When the frequency oscillator is con-
nected and an output is displayed on
the electronic readout device, this indi-
cates that the turbine flowmeter cable
assembly is defective and should be
replaced. If no output is displayed, the
turbine flowmeter cable assembly is
good and the problem lies within the
electronic readout device.
Checking the Electronics
Using the frequency oscillator and
the cable that is supplied, connect
Symptom
No output is
displayed or
registered
More volume/
output than
displayed or
registered.
Less volume/
output than
displayed or
registered.
12
Troubleshooting Reference Guide
Probable Cause
Defective magnetic pickup
Foreign matter obstructing the
turbine flowmeter rotor
Defective turbine flowmeter
internals
Defective turbine flowmeter
cable assembly
Defective electronic/readout
device
Rotor may drag due to foreign
matter obstruction
Magnetic pickup not screwed
down all the way into the
turbine flowmeter body. Caus-
ing it not to detect all the rotor
blades as they pass.
Turbine flowmeter installed
backwards.
Turbine flowmeter rotor in-
stalled backwards.
K-factor is too high in elec-
tronic/readout device.
Caused by entrained air in the
process line.
K-factor is too low in
electronic/readout device.
it to the electronic readout device,
the same as you would a turbine
flowmeter cable assembly. Once the
frequency oscillator is connected, if no
output is displayed on the electronic
readout device, check to ensure that
the power is on, the fuses are good,
and the correct K-factor is dialed/
programmed into the electronic
readout device. After verification of
these items, if there is still no output
displayed and/or registered, then the
manufacturer of the electronic readout
device should be consulted.
Solution
Refer to the Checking the
Magnetic Pickup section.
Refer to the Checking the
Turbine Flowmeter section.
Refer to the Checking the
Turbine Flowmeter section.
Refer to the Checking the
Cable Assembly section.
Refer to the Checking the
Electronics section.
Refer to the Checking the
Turbine Flowmeter section
Screw the magnetic pickup all
the way down into the turbine
flowmeter body. Hand-tighten
only.
Install the turbine flowmeter in
accordance with the process
flow direction.
Install the turbine flowmeter
rotor in accordance with the
process flow direction.
Verify K-factor used. K-factor
should be decreased.
Install an air eliminator up-
stream of turbine flowmeter.
Verify K-factor used. K-factor
should be increased.