Ameda PENGUIN Instrukcja obsługi - Strona 15

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Podgrzewacz do żywności Ameda PENGUIN. Ameda PENGUIN 16 stron. Deluxe nutritional warmers

Ameda PENGUIN Instrukcja obsługi
Guidance and manufacturer's declaration – electromagnetic immunity
The Ameda Penguin Warmer is intended for use in the
electromagnetic environment specified below.
Immunity test
Conducted RF IEC
61000-4-6
Radiated RF IEC
61000-4-3
NOTE 1
At 80 MHz and 800 MHz, the higher frequency
range applies.
NOTE 2
These guidelines may not apply in all situations. Electro-
magnetic propagation is affected by absorption and
reflection from structures, objects and people.
a Field strength from fixed transmitters, such as base stations
for radio (cellular/cordless) telephones and land mobile radios,
amateur radio, AM and FM radio broadcast and TV broadcast
cannot be predicted theoretically with accuracy. To assess the
Recommended separation distances between portable and mobile
RF communications equipment and the Ameda Penguin Warmer
The Ameda Penguin Warmer is intended for use in an
electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the Ameda Penguin
Warmer can help prevent electromagnetic interference by
maintaining a minimum
Rated maximum
output power of
transmitter (W)
0,01
0,1
1
10
100
For transmitters rated at a maximum output power not listed
above, the recommended separation distance d in meters (m) can
be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
IEC 60601 test level
3 V
0,15 MHz – 80 MHz
80% AM at 1 kHz
6V in ISM and amateur
radio bands between
0,15 MHz and 80 MHz
80% AM at 1 kHz
10 V/m
80 MHz – 2,7 GHz
80% AM at 1 kHz
9 – 28 V/m
At IEC 60601-1-2: 2014
Table 9 frequencies
Separation distance according to frequency of transmitter (m)
150 kHz to 80 MHz
d = 1,2√P
0,12
0,38
1,2
3,8
12
The customer or the user of the Ameda Penguin Warmer should
assure that it is used in such an environment.
Compliance level
3 V
0,15 MHz – 80 MHz
80% AM at 1 kHz
6V in ISM and amateur
radio bands between
0,15 MHz and 80 MHz
80% AM at 1 kHz
10 V/m
80 MHz – 2,7 GHz
80% AM at 1 kHz
9 – 28 V/m
At IEC 60601-1-2: 2014
Table 9 frequencies
electromagnetic environment due to fixed RF transmitters, an
electromagnetic site survey should be considered. If the measured
field strength in the location in which the Ameda Penguin Warmer is
used exceeds the applicable RF compliance level above, the Ameda
Penguin Warmer should be observed to verify normal operation. If
abnormal performance is observed, additional measures may be
necessary, such as re-orienting or relocating the Ameda Penguin
Warmer.
b Over the frequency range 150 kHz to 80 MHz, field strengths
should be less than 10 V/m.
distance between portable and mobile RF communications
equipment (transmitters) and the Ameda Penguin Warmer as
recommended below, according to the maximum output power
of the communications equipment.
80 MHz to 800 MHz
d = 1,2√P
0,12
0,38
1,2
3,8
12
NOTE 1
At 80 MHz and 800 MHz, the separation distance for the
higher frequency range applies.
NOTE 2
These guidelines may not apply in all situations.
Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
15
Electromagnetic environment – guidance
Portable and mobile RF communications equip-
ment should be used no closer to any part of the
Ameda Penguin Warmer,
including cables, than the recommended
separation distance calculated from the equation
applicable to the frequency of the transmitter.
Recommended separation distance
d = 1,2√P
d = 1,2√P 80 MHz to 800 MHz
d = 2,3√P 800 MHz to 2,7 GHz
Where P is the maximum output power rating
of the transmitter in watts (W) according to the
transmitter manufacturer and d is the recom-
mended separation distance in meters (m).
Field strengths from fixed RF transmitters, as
determined by an electromagnetic site survey,
should be less than the compliance level in each
frequency range.
b
Interference may occur in the vicinity of equip-
ment marked with the following symbol:
800 MHz to 2.7 GHz
d = 2,3√P
a
0,23
0,73
2,3
7,3
23