Coastal WEATHERPAK MTR Podręcznik użytkownika - Strona 9

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Stacja pogodowa Coastal WEATHERPAK MTR. Coastal WEATHERPAK MTR 20 stron.

Connecting to a Computer with Serial to USB Converter
2-2.3
In the event the computer does not have a USB port, you must employ a "Serial to USB" converter, which is
available at your local computer supply store. Connect the Serial cable to the converter. Follow the directions
provided with the Serial to USB device.
2-2.4
Connecting to a Computer with the Ethernet Port
This method is to be employed only if the Receiver/Display must be connected to a network. Please contact
Coastal Environmental Systems, Inc. for further information.
2-3
TRIPOD AND WEATHERPAK
Assemble the tower in the following manner:
1.
Insert and lock the legs onto the bottom section of the
tower, forming the tower's tripod base.
2.
Align the slot on the WEATHERPAK
on the quick release and push straight in. DO NOT
"screw" the WEATHERPAK
connector. The KamLock provides a precision sealed fit
and may require an extra push to seat the
®
WEATHERPAK
properly. Once the weather station is
properly seated, press the arms of the clamp down to
assure a tight fit. The battery indicator light (on the
tower junction box) should illuminate when the
®
WEATHERPAK
is properly seated into the KamLock.
3.
Place the entire unit (upper tower section and
WEATHERPAK
) onto the tripod, engage the twist-lock
and turn clockwise ¼ turn.
4.
The WEATHERPAK
When the WEATHERPAK
KamLock connector, it will stop sampling and shut itself
off.

CHAPTER 3 SYSTEM OPERATION

Once set up, the WEATHERPAK
weather conditions and transmits data to the Receiver/Display
every 30 seconds. (See "Data Line Interpretation" in Section 3-
3.5, for additional information.)
The Receiver/Display takes approximately 20-30 seconds to
complete a boot-up routine. When this process is complete, it is ready to accept the first transmission from the
®
WEATHERPAK
. The data may now be viewed on the display or viewed and archived using Coastal Environmental
Systems' optional INTERCEPT™ software. Plume modeling software requires five minutes of data before a valid plume
can be presented,

CONFIGURING THE DISPLAY

3-1
During the boot-up process two touch screen buttons will appear labeled Configure and Skip Configuration.
When selected, the Configure button opens a series of screens which allow the operator to select from several
data display configuration choices. Once these selections have been made (typically the first time you boot-up
your new system), the values are stored in memory. It is not necessary to configure the system every time it is
used. The configuration screen will time-out in approximately five seconds, or you can touch the Skip
Configuration button to proceed. Configuration choices are:
P/N: 0302-140-001 Rev. D
®
SET UP
with the guide pin
onto the KamLock
is now running and sampling data.
is removed from the
automatically begins sampling
®
WEATHERPAK
User's Manual
Figure 3 – Tower Set-up
MTR