Coastal Climate Control Guardian Podręcznik
Przeglądaj online lub pobierz pdf Podręcznik dla Panel sterowania Coastal Climate Control Guardian. Coastal Climate Control Guardian 2 stron. System monitor and speed control
Guardian
Description:
The Coastal
Thermostat/ Thermometer, a compressor speed adjustment knob, and a diagnostic fault LED. The panel is supplied with
a 10' thermostat sensor and a 10' control cable that connects to a Danfoss compressor controller. If a Merlin SSC is
installed on the compressor controller, "AUTO" setting will give automatic speed control, otherwise there will be no
automatic speed control capability. A Power Terminal Multiplier circuit board is included to facilitate easy power
connections to the Danfoss controller, and a 2 amp in‐line fuse is installed in the positive power feed wire. Standard
model is for operation on 12v power supplies only. 24v versions available on request.
Location:
The panel is designed to be mounted on a vertical surface, secured by the four screws provided. Care
must be taken to ensure that the location chosen will not subject the panel or its components to splashing or running
water, steam, corrosive gasses, excessive vibration, or physical damage. Ideally the location will allow the 10' thermostat
sensor and control cable to be installed without being extended. If it is necessary to extend either cable, the electrical
joints should be soldered. The panel requires a cut‐out measuring 4.5" x 1.5", and a depth of 3".
Installation:
The Power Terminal Multiplier is to be installed on the top two terminals of the Danfoss controller. This
provides two sets of + and – terminals: one set for the incoming 12v power feed from the distribution panel via a
breaker, and one for the power supply to the
Multiplier mate correctly with the male pins. The
sensor and control cables run to their respective locations. The control wires connect to the Danfoss controller as shown
below. The thermostat sensor should ideally be located at mid‐height in the box, and not on a wall that has any portion
of an evaporator mounted on it. The sensor should be isolated from the box wall with a plastic tie or similar.
Wiring:
Power Terminal Multiplier
Cable to Guardian panel
Brown
Note 2
White
-
System Monitor and Speed Control
Guardian
comprises a panel measuring 5"w x 2"h that incorporates a Coastal MK II Digital
Guardian
Guardian
Black
Fuse
Red
Green
Blue
Note 1
Orange
Danfoss Standard 101N0210 Compressor Controller
. Ensure that the female connectors on the Power Terminal
panel is then mounted and secured and the thermostat
+
+
F
NOTES:
1 – If Merlin SSC fitted, Blue and Orange
D
wires plug on to "C" and "T" on Merlin.
C
2 – Brown and White wires are spare and not
P
used on standard installations. These may be
used as switched wires from a second digital
T
thermostat for a spillover fan, etc.
12v or 24v Power
Supply input
12v switched output for
Fan or Pump Relay
Over: