SPECIFICATIONS

The instrument complies with: EN61010-1.
Insulation: Class2, Double insulation.
Overvoltage category: CATII - 1000V.
Display: 2000 counts LCD display with function indication.
Polarity: Automatic, (-) negative polarity indication.
Overrange: "OL" mark indication.
Low battery indication: The "BAT" is displayed when the
battery voltage drops below the operating level.
Measurement rate: 2 times per second, nominal.
Operating environment: 0 o C to 50 o C (32 o F to 122 o F) at
< 70 % relative humidity.
Storage temperature: -20 o C to 60 o C (-4 o F to 140 o F) at <
80 % relative humidity.
For inside use, max height: 2000m
Pollution degree: 2
Power: One 9V battery , NEDA 1604, IEC 6F22.
Dimensions: 195 (H) x92 (W) x 38 (D) mm
5
Weight: Approx.: 380g.
Accuracy is given at 18 o C to 28 o C (65 o F to 83 o F), less
than 70 % RH
DC Voltage
Range
Resolution
200.0mV
0.1mV
2.000V
1mV
20.00V
10mV
200.0V
100mV
1000V
1V
Input Impedance: 10M:.
200mV range Maximum Input: 250V dc or 250V ac rms.
Maximum Input: 1000V dc or 700V ac rms.
AC Voltage
Range
Resolution
2.000V
1mV
20.00V
10mV
200.0V
100mV
700V
1V
Input Impedance: 10M:.
Frequency Range:50 to 400Hz
Maximum Input: 1000V dc or 700V ac rms.
DC Current
Range
Resolution
2.000mA
1uA
20.00mA
10uA
200.0mA
100uA
20.00A
10mA
Accuracy
+0.5% of rdg + 2 dgts
+0.8% of rdg + 2 dgts
Accuracy
+1.0% of rdg + 3 dgts
+1.2% of rdg + 5 dgts
Accuracy
+1.0% of rdg + 3 dgts
+1.5% of rdg + 3 dgts
+2.5% of rdg + 10 dgts