Aktakom AMM-1081 Instrukcja obsługi - Strona 6
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Multimetr Aktakom AMM-1081. Aktakom AMM-1081 20 stron. Smart multimeter
Operating
humidity
Power
Supply
Power consumption DC 3 mA.
Weight
Dimension
Accessories
Included
Optional
accessories
2-2 Electrical specifications (23± 5
DC/AC Voltage
Range
Resolution
Accuracy
Input impedance
Over load protection
Remark
Less than 80% RH.
Green power :
Power from the handy generator,
battery is no need.
Battery power :
DC 3V battery ( CR-2032 ) x 2 PCs.
340 g/0.75 LB.
152 x 78 x 45 mm
( 6.0 x 3.1 x 1.8 inch )
Red and Black Test Leads........ 1 Set
Instruction Manual................... 1 PC
Full line adapters :
ACA/DCA current adapter,
Tachometer adapter,
Humidity adapter, Pressure adapter,
Light adapter, EMF adapter,
Sound level adapter,
High voltage probe.
* auto range
6 V /60 V/600 V
0.001 V /0.01 V/0.1 V
DCV :
± ( 1 % + 2d )
ACV :
± ( 1.2 % + 5d )
10 M ohm.
AC/DC 600 V.
* The input impedance is 10 Mega ohm.
* ACV specification be tested on sine
wave 50/60 Hz.
* For smart function ,the ACV start
measurement voltage is larger than
400 mV ± 100 mV.
3
www.tmatlantic.com
)
℃