3.) Power connection
Insert the plug into the socket and wait for the LED indicator to light up briefly.
4.) Switching the air purifier on or off
Press the ON / OFF switch. The air purifier acknowledges the command with a short beep, the operating light stops
flashing, the LED display switches on and the air purifier starts its operation. The default operating mode is air
sensor mode (Auto mode).
To switch off, press the ON / OFF switch for approx. three seconds. The air purifier acknowledges the switch-off
with a short beep and the LED display switches off.
5.) Setting the different operating levels or the auto mode
Manual operation:
Press the "FAN SPEED" button and select your desired power level by pressing it repeatedly. There are three air
circulation levels:
Night mode (Silent) > Particularly quiet operation with very low air circulation.
Weak fan stage
Powerful fan stage
(See chart below).
Night mode
Weak fan stage
Powerful fan stage
Auto mode
Auto mode:
Press the "FAN SPEED" button until the Auto mode indicator lights up in the display panel. The air sensor then
switches on and automatically starts measuring the air quality.
(See above chart).
Please note that the proper air sensor function is only available after approx. two minutes !
If the determined air quality is "good", the air purifier automatically switches to a weak fan stage. If the result is the
opposite and the air quality is inferior or poor, the air purifier switches to a strong fan stage.
Notes on the air sensor
The air sensor is located in a small compartment on the side and reacts to particles in the air and thus always gives
only a tendency of the air quality. Since it is a tendency (similar to a weather station), this function cannot provide a
100% reliable statement about pollutants in the room air or about the entire area of a room.
Furthermore, stronger operating fluctuations may occur from time to time (jump from red to green and vice versa),
as the air sensor probe reacts to particles and volatile organic compounds (VOCs) in the room and is also exposed
to draughts.
Cleaning the air sensor
To ensure trouble-free operation of the air sensor (Auto mode), we recommend cleaning the air sensor
approximately every two months. First take a soft brush to clean the air slots above and below the air sensor.
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany