Aktobis WDH-AP1101 Podręcznik - Strona 7
Przeglądaj online lub pobierz pdf Podręcznik dla Oczyszczacz powietrza Aktobis WDH-AP1101. Aktobis WDH-AP1101 11 stron.
Light sensor
The air purifier is equipped with a light sensor on the control panel. The light sensor is only activated in the
operating mode "Air sensor operation" (Auto Mode). If the air purifier is in the dark for three minutes (night), the
LED display is automatically dimmed and the unit switches to night mode (weak air circulation). If the unit is again
in a bright environment (day), the air purifier restarts its normal air sensor operation (Auto Mode)
7.) Filter change / Filter change indicator
The unit is equipped with a filter change indicator. Depending on the duration of use and the degree of
contamination, this may be indicated by a beep every 30 minutes and a red light on the "FILTER" button !
This indicates that the prefilter should be cleaned and/or the fine filters replaced.
Notification: Disconnect the mains plug before cleaning/replacing the filters. In order to achieve optimum filter
results, we strongly recommend that you only use original filters from the manufacturer.
After the filter change indicator lights up, there are still 24 operating hours available, then the unit switches off the
filter operation automatically for safety and efficiency reasons.
After the prefilter has been cleaned and/or the fine filters have been replaced, it is necessary to press the reset
button ! The reset button for the filters is located in the air sensor compartment. Open the air sensor compartment,
then press the reset button for approx. 3-5 seconds until you hear a short "click". Then close the air sensor
compartment again. Please note that the air purifier must be switched on for resetting! Finally, the air purifier should
be switched off and briefly disconnected from the power supply (pull the mains plug). Your air purifier is then fully
operational again !
See following diagrams / pictures:
8.) Additioal
The air purifier can be controlled and adjusted both via the LCD display and via the remote control.
A button cell CR2032 (3V) is required to operate the remote control.
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: [email protected]