Aktobis EDH-FGA1263B Instrukcja obsługi - Strona 9
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Klimatyzator Aktobis EDH-FGA1263B. Aktobis EDH-FGA1263B 14 stron.
11. Other operating instructions
11.1. To ensure a long service life of the compressor, please do not switch the unit off and on again within 3
minutes. (Switching the unit off and then on again shortly afterwards will damage the compressor).
11.2. The cooling circuit (compressor) switches off as soon as the ambient air is below the target temperature.
However, the air circulation continues. If the ambient air rises above the target temperature, the cooling circuit
(compressor) also switches on again automatically.
11.3. This air conditioner is equipped with a defrost function. If the unit is operated for a long time or in cool ambient
air, the cooling circuit (compressor) may switch off briefly until the ice that has formed on the cooler unit has
defrosted.
12. Important operating and safety instructions regarding the refrigerant R290 in this unit
Read these instructions carefully !
This air conditioner operates with the refrigerant R290, which is highly flammable and explosive. Therefore,
please take special care that the copper lines are not damaged at any time!
The appliance should not be placed in a room where other appliances are operated at the same time which
have an electric heater or an open flame.
Please note that the refrigerant is odourless and therefore a leak cannot be detected immediately by an
emerging odour !
Make sure that the outlet of the exhaust air is always given and not obstructed by other objects !
Only appropriately trained specialists are permitted to carry out repairs to the cooling lines and the
compressor! Always contact a specialist in case of a problem !
Ensure a minimum distance of at least 50cm from open flames and heating elements !
Condensation:
Some condensation forms in the unit during the cooling process. This side effect is caused by the extraction of
moisture from the ambient air during the cooling process. This condensation water is collected and fed into the
integrated lower condensation tank. If the integrated condensation tank is full, the compressor and the motor of the
air conditioner switch off. In addition, this condition is signalled to you by the signal light (K) "Condensation tank is
full" on the control panel and by a beep !
To drain the condensation water tank and
thereby reactivate the air conditioner, please
follow the steps below:
1. Switch off the air conditioner and avoid
moving the unit when the condensation
tank is full.
2. Position a drip tray below the drain hole
for the condensation water.
3. Unscrew the cap and then remove the
rubber plug by pulling it out horizontally.
Now the condensation water can drain
out of the tank.
4. If your drip tray is full but there is still
water in the condensation tank, simply
put the rubber plug back on the drain
hole and then empty the drip tray first.
5. Repeat this procedure until the
condensation tank is completely empty.
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: [email protected]