The following diagram shows the electrical schematic for the rotary phase converter:
Firmly snap in the green, yellow/white and red switch
terminals into the pushbutton switch body. (In the image
at right, a clear enclosure cover is used for clarity.)
f. Wire the idler:
240V:
Bolt idler leads 4, 5 & 6 together. DO NOT ground 4, 5, and 6! Insulate this
connection with electrical tape, ceramic electrical tape, or heat shrink
tubing. Connect the ground line to the ground screw inside the motor
conduit box. Inside the phase converter panel box, connect terminal A to
(1,7), terminal B to (2,8) and terminal C to (3,9). Insulate these connections
separately. Hardware for these connections is provided. DO NOT use wire
nuts for ANY idler connections!
8