sense a fire on another floor of a home. For example, a
basement smoke alarm may not detect a fire which started on
the first or second floor.
• Smoke alarms may not be heard. The loudness of the horn in
SMOKE ALARM MANUAL
your alarm meets current standards. However, the sound may
Ionization Type Model - 120 VAC Hardwire
be blocked by distance, closed doors, or ambient noise such as
with Battery Back-Up & Alarm-Pause
®
Feature
traffic or a stereo. Smoke alarms may not be heard by persons
who are hard of hearing.
For these reasons, a smoke alarm should be installed in every
• Model SA379 - Professional Multi-Location
room or at least on every level of your home. American
- 120 Volt AC Hardwire Smoke Alarm with Battery Back-Up
Sensors recommends that hardwire AC Powered smoke alarms
and Alarm-Pause
®
feature. This smoke alarm is also
be interconnected, so that one alarm will trigger all other
interconnectable with up to 11 other units.
Smoke alarms to sound their alarms.
• Smoke alarms are not fool-proof. Smoke alarms may not
Important information about your smoke alarm
always sense every kind of fire. They cannot be expected to
• Install alarms outside of every bedroom area and on every floor
sense fires caused by carelessness or by safety hazards. They may
of your home. Please refer to Section 3 "Where to Locate
not give early warning of fast growing fires caused by smoking
Smoke Alarms" for details.
in bed, violent explosions, escaping gas, improper storage of
• Install the alarm as close as possible to the center of the
flammable materials, overloaded electrical circuits, natural
ceiling.
causes such as lightning, children playing with matches, or
• Your Smoke Alarm is packaged with the back-up battery
arson.
reversed. Connect it before mounting the unit. Ensure proper
• Smoke alarms are not substitutes for property, disability, life
polarity of the battery. Alarm will "beep" if battery is reversed
or other insurance of any kind. Home owners and renters
and the unit is receiving AC power.
should continue to insure their lives and property. Consult your
• Replace the back-up battery if the smoke alarm beeps
insurance agent.
approximately once every 45 seconds (low battery warning).
• Smoke alarms have limited lives. One or more of the many
• Test the alarm weekly by pressing and holding the test button
components could fail at any time. Therefore, test your smoke
for up to 20 seconds until the alarm sounds.
alarm weekly. Clean and take care of it as described in this
manual. Repair or replace the smoke alarm when it fails to test
• The model described in this manual is designed for single
properly. Your smoke alarm should be replaced if it is ten
family residences, including homes and apartments.
years old.
Smoke Alarm Safety Features
•
• Battery Back-Up - 120VAC operation with battery back-up
(included) to power your smoke alarm in the event of a power
interruption.
• Alarm-Pause
®
Silencer - Silence your alarm for approximately
10 minutes, by momentarily pressing the Alarm-Pause
®
Silencer
There are two different types of smoke alarm technology
currently in general use: ionization and photoelectronic. While
button. Ideal for use when non-emergency smoke causes
nuisance alarms. Automatically resets after 10 minutes. During
both types of technology are suitable for general residential use,
an ionization alarm will normally respond faster to fast flaming
Alarm-Pause
®
the unit will "beep" every 45 seconds to remind
fires, while a photoelectronic alarm may be more sensitive to
the household that the alarm has been silenced. In the event of
detecting slow smoldering fires. Because home fires develop in
a heavy build-up of smoke during the pause period, the alarm
different ways and are often unpredictable in their growth, it is
will resume sounding. For interconnected units, only the alarm
impossible to predict which type of alarm will provide the earliest
which had the Alarm-Pause
®
Silencer button activated will be
warning. For best home protection install at least one
in Alarm-Pause
.
®
photoelectronic and one ionization smoke alarm on each level of
• Dual-Ionization Chambers - Advanced design responds to
your home. Model SA700 is a 2 in 1 smoke alarm utilizing both
visible or invisible particles of combustion (smoke) to sense
ionization and photoelectronic technology. Model SA379 is an
fires in their earliest stages. Compensates for changes in
ionization type smoke alarm.
humidity and temperature to virtually eliminate "nuisance"
alarms caused by normal atmospheric changes in the home.
A photoelectronic smoke alarm senses smoke using an electronic
• Operating Lights (LED's) - A continuous green light located
photo receptor to sense the scattering of light by smoke particles.
The American Sensors model SA388 is a photoelectronic type
behind the slotted case indicates the smoke alarm is receiving
AC power. A red light that flashes approximately every 45
smoke alarm.
seconds confirms that the battery is operational.
• Low Battery Warning - If powered only by battery the unit
2. SAFETY TIPS
"beeps" approximately every 45 seconds for up to 30 days when
Properly installed and maintained smoke alarms are an essential
the battery needs replacing. If the unit is receiving continuous
part of a good home fire safety program. Your fire safety program
AC power, the low battery beep will continue indefinitely.
should also include a review of fire hazards and the elimination
• Battery Removal Indication - Battery compartment drawer is
of dangerous conditions whenever possible. Consider the
designed to resist closing when the battery is removed. A visual
following tips:
reminder to replace the battery. Low battery warning beep is
• Use smoking materials properly. Never smoke in bed.
disabled with the drawer open.
• Keep matches and cigarette lighters away from children.
• Interconnection - Interconnection facilities for up to 11 other
• Store flammable materials in proper containers. Never use
units, using only three wires, including AC power. When one
them near an open flame or sparks.
alarm sounds, all properly interconnected smoke alarms follow.
• Keep electrical appliances in good condition. Do not overload
NOTE: Interconnect only to the models specified in Section 6.
electrical circuits.
• Alarm Source Indicator - Only the red operating light in the
• Keep stoves, fireplaces, chimneys, and barbecue grills grease
unit originating the alarm will flash rapidly in the event of an
free. Make sure they are properly installed and away from any
alarm. With interconnected units, an easy check to determine
combustible materials.
the originator.
• Keep portable heaters and open flames such as candles away
• Locking Keys - Two auxiliary locking keys provided. Use key #
from combustible material.
1 to lock mounting plate to smoke alarm. Use key # 2 to lock
mounting plate and battery drawer to the smoke alarm to
• Do not allow rubbish to accumulate.
prevent opening of the battery drawer. Reduced risk of
• Keep a supply of extra batteries on hand for your battery
unauthorized removal.
powered smoke alarms.
• Sensitivity Test Button - Tests sensitivity, as well as circuitry,
• Do not stand too close to the alarm when the unit is in alarm
battery and horn. With interconnected units, activating test
as the loud horn could damage your hearing.
button on one unit will cause all units to sound. An important
and convenient check of system integrity.
• Quick Disconnect Power Connection - For easy installation.
WARNING
!
Connect the wires separately from the unit and then plug into
a nuisance alarm. Clear the area of smoke by opening doors or
back of the unit.
windows or fanning the smoke away. Use the Alarm-Pause
• Detachable Base Plate - For easily securing the alarm to the
button on model SA379 to silence nuisance alarms.
junction box.
Most important, when fire strikes, a prepared and practiced
escape plan can make the difference between life and death.
CONTENTS OF THIS MANUAL
Develop an escape plan and practice it with the entire family,
including small children.
1. CAPABILITIES AND LIMITATIONS OF SMOKE ALARMS
• Ensure all family members are familiarized with the alarm
2. SAFETY TIPS
signal.
3. WHERE TO LOCATE SMOKE ALARMS
• Prepare an escape plan. Draw a Floor Plan of Your Home and
4. NFPA RECOMMENDATIONS
determine two exits from each room. There should be a way to
5. LOCATIONS TO AVOID
get out of each bedroom without opening the door.
6. INSTALLATION AND TESTING
• Have Fire Drills Often. Practice your Escape and BE
7. BATTERY REPLACEMENT
PREPARED.
8. MAINTENANCE AND TROUBLESHOOTING
• Decide on a meeting place at a safe distance from your home.
9. LIMITED WARRANTY
10. OTHER AMERICAN SENSORS PRODUCTS
IN CASE OF FIRE
• Don't waste time collecting possessions after a fire starts.
1. CAPABILITIES AND LIMITATIONS OF SMOKE ALARMS
• Arouse all occupants and leave the building. Your most
valuable possession is your life.
American Sensors smoke alarms are designed to provide early
warning of fire and smoke at reasonable cost. Early warning can
• Doors can mean escape or death. Never open doors without
mean the difference between a safe escape and no escape at all.
first checking for heat. Test them with your hands, if they feel
While smoke alarms can provide invaluable protection for you
warm, fire may be walled up behind them - leave closed and
and your family, they do have limitations.
find another escape route.
• Smoke alarms cannot work without power. Battery operated
• Call the fire department from OUTSIDE the building.
alarms will not work without proper batteries, with dead
• If trapped inside, stay close to the floor, cover mouth with
batteries or if batteries are not properly installed. AC powered
cloth, conserve breath as you crawl to safety.
alarms will not work if their AC power supply is cut off by an
• Keep all doors and windows closed except for escape purposes.
electrical fire, an open fuse, a circuit breaker or any other
• NEVER re-enter a burning building.
reason.
If you are concerned about the reliability of either batteries or
• Keep your family in a pre-arranged meeting place after your
your AC power supply for any of the above reasons, you should
escape.
install in your home both AC and battery powered smoke
alarms for added security. This American Sensors Smoke Alarm
model SA379 is AC powered with battery back-up and offers
superior protection from the dangers of smoke and fire.
• Smoke alarms are incapable of sounding the alarm until
smoke reaches the sensing chamber. Anything preventing
smoke from reaching the alarm may delay or prevent an alarm.
A smoke alarm cannot detect fire in the walls, chimney or roof
Your local fire department may be able to offer you additional
unless and until a significant amount of smoke reaches the
ideas for safety and escape plans in the home.
alarm. A closed door may prevent smoke from reaching an
alarm on the other side of the door. A smoke alarm may not
3a. WHERE TO LOCATE SMOKE ALARMS
As a minimum, smoke alarms should be located between
sleeping areas and potential sources of fire such as a kitchen,
heated garage or basement. In single storey homes with one
sleeping area, an alarm should be installed in the hallway outside
the bedrooms (see Figure 1). In single storey homes with two
separate sleeping areas, a minimum of two alarms are required,
one outside each sleeping area (see Figure 2). In multi-level or
split-level homes, as a minimum, an alarm should be installed
outside each sleeping area, in the basement and at every level of
the home (see Figure 3).
• In every room of your home (except the bathroom): Research
indicates that substantial increases in warning time can be
obtained with each properly installed, additional alarm.
• In bedrooms: In anticipation of fires originating within these
rooms, caused by faulty wiring, lamps, appliances, smoking or
other hazards.
• In hallways: At a distance no greater than 13 feet (4 meters)
from the farthest wall and no greater than 26 feet (8 meters)
from the next alarm.
• In the center of a room or hallway: As it is impossible to
predict the source of a fire. If it is necessary to place the alarm
on a wall, always locate the top of the smoke alarm 4-6 inches
(10-15 cm) from the ceiling.
• As needed: To compensate for closed doors and other obstacles
that may interfere with the path of smoke to an alarm. They
may also prevent occupants on one side of a closed door from
hearing a alarm on the other side of the door.
Model SA379 - Professional Multi-location Hardwire with
Battery Back-Up Model can be located in any area of the home.
Its Alarm-Pause
®
feature makes it ideal in the kitchen area
Ionization Technology vs.
to silence nuisance alarms. Do not install it directly over
Photoelectronic Technology
a stove, toaster or dishwasher.
Smoke Alarms
READ "CAPABILITIES AND LIMITATIONS OF SMOKE
ALARMS" in Section 1 of this manual.
Your local fire department or insurance company may be able to
give you further advice on the best smoke alarm locations in your
home. Call them and ask.
Kitchen
Bedroom Bedroom
Dining
Dining
TV Room
Living Room
Living Room
Bedroom
Bedroom
Figure 1
Smoke alarms for limited protection
Additional smoke alarms for better coverage
These diagrams show smoke alarm locations as
recommended as above in 3a.
3b. WHERE TO LOCATE SMOKE ALARMS IN MOBILE
HOMES AND RECREATIONAL VEHICLES (RV's)
Note: Power supply must be 120 Volts AC for model
SA379.
In mobile homes and RV's built after 1978 locate the smoke
alarm as described above.
Older mobile homes and RV's may have little or no insulation
compared to the ones built post 1978. These uninsulated
exteriors can disrupt airflow around the smoke alarm in hotter or
colder weather. Locate the alarm only on interior walls 4" to 6"
(10 to 15 cm) from ceiling 1. if you own an older mobile home or
RV, or 2. if you notice the exterior walls and/or ceiling are
noticeably cold or warm or 3. if you are uncertain about the
quality of insulation.
Regardless of the age of the mobile home or RV, locate alarms
throughout to ensure maximum protection. Follow the location
instructions in this manual.
4. NFPA RECOMMENDATIONS
For your information, the National Fire Protection
Association's Standard 72, Section 2-2.1.1.1, reads as follows:
2-2.1.1.1 Smoke alarms shall be installed outside of each separate
sleeping area in the immediate vicinity of the bedrooms
and on each additional storey of the family living unit,
including basements and excluding crawl spaces and
unfinished attics. In new construction a smoke alarm
also shall be installed in each sleeping room.
Never disconnect the battery or the AC
A-2.5.2.1 Smoke Detection - Are More Smoke Alarms Desirable? The
power on any type of smoke alarm to silence
required number of smoke alarms might not provide reliable early
warning protection for those areas separated by a door from the
®
areas protected by the required smoke alarms. For this reason, it is
recommended that the householder consider the use of additional
smoke alarms for those areas for increased protection. The
additional areas include the basement, bedrooms, dining room,
furnace room, utility room, and hallways not protected by the
required smoke alarms. The installation of smoke alarms in
kitchens, attics (finished or unfinished), or garages is not normally
recommended, as these locations occasionally experience
conditions that can result in improper operation.
5. LOCATIONS TO AVOID
Avoid locations where smoke may not reach the alarm in time
to provide early warning, or where the alarm may not be
effective.
DO NOT PLACE SMOKE ALARMS:
• In turbulent air from fans, doors, windows, etc. The rapid air
movement may prevent combustion particles from entering the
alarm.
• In dead air spaces such as at the peak of an "A" frame ceiling.
"Dead air" at the top may prevent smoke from reaching the
alarm in time to provide early warning. In rooms with simple
sloped, peaked or gabled ceilings, install smoke alarms on the
ceiling 3 feet (90 cm) from the highest point of the ceiling.
Note: For complex ceiling structures, consult a safety expert for
the number of alarms required and the best locations.
• In very hot or cold areas where the temperature exceeds 100
(38
0
C) or falls below 40
0
F (5
• Less than 6 inches (15 cm) from the wall when mounted on
the ceiling.
Nuisance alarms could result when smoke alarms are located
where interference may occur with the sensing chamber. To
avoid nuisance alarms, DO NOT place smoke alarms:
• In high humidity areas such as bathrooms and attics. Place
smoke alarms at least 10 feet (3 meters) away from bathrooms.
• In insect-infested areas.
• In poorly ventilated kitchens or garages.
• In very dusty and dirty areas.
• Near fluorescent lights. Place smoke alarms at least 5 feet (1.5
meters) from fluorescent lights.
This smoke alarm is suitable for residential
WARNING
!
use. It is not to be connected to a
commercial or industrial fire alarm panel.
6. INSTALLATION AND TESTING
Locking Keys - Optional
This model has optional locking keys to better secure either the
alarm and/or the alarm and back-up battery to inhibit
unauthorized removal. See point 16 in this section for more
details on this feature.
A. Installation
Mount to any standard or rectangular junction box with a
minimum depth of 1 inch (25mm). 120V AC, 55mA operation.
WARNING: Wiring should only be installed by a licensed
electrician in accordance with the National Electrical Code and
local codes.
WARNING: The circuit used to power the alarm must be a 24
hour voltage circuit that cannot be turned off by a switch or a
ground fault interrupter. It is highly recommended that smoke
alarms be wired on a separate circuit (one with no other lights or
appliances) to ensure maximum reliability of AC power supply.
For installation of Smoke Alarms in Dwelling Units, it is
important to follow the National Electrical Code and local codes.
1. Electricity must be turned off at service entrance before
beginning installation to prevent electrical shock or
equipment damage.
2. Location must comply with applicable building codes.
3. Install a junction box where you plan to install the alarm.
Use standard 14 gauge wire.
4. Grasp the tab on the battery drawer and slide it straight out.
5. Reposition the battery in its compartment as shown on the
markings in the drawer.
6. Push the drawer straight in until it is flush with the housing.
7. Test as recommended in "Operation" section.
8. Connect black and white wires, color to color, from power
connector to AC power leads.
9. For multiple station, use the orange wire for interconnection.
If unit is not to be interconnected, cap unused wire.
10. Loosen or remove screws from junction box.
11. Attach flat side of mounting plate and tighten screws to fit
snugly against junction box and ceiling or wall.
Kitchen
Bedroom
quick disconnect
power connector
Bedroom
Bedroom
Hall
Bedroom
Figure 2
Living
Room
Hall
Kitchen
Figure 3
Basement
Furnace
mounting plate
paper gasket (not shown-fits in between)
12. Bring power connector through center opening.
13. Slip the paper gasket supplied with the alarm over the power
connection and then onto the mounting plate so that the
four plastic tabs on the mounting plate will hold the gasket in
place. The gasket will prevent downward air currents from
entering the smoke alarm through holes in the back of the
alarm. Unless blocked off, downward air currents prevent
smoke from entering the alarm.
WARNING: IT IS IMPERATIVE THAT YOU INSERT
THE GASKET WHEN INSTALLING YOUR SMOKE
ALARM.
14. Plug wire connector into the back of the alarm.
15. Align the plug area on the smoke alarm with the cut out in
the gasket and place the smoke alarm in the mounting plate,
turn clockwise to fasten it to the mounting plate.
16. If auxiliary lock is desired insert either key # 1 or # 2 into the
slot marked "Key Slot" in the base of the alarm just below the
battery drawer. Locking key should "click" into position and
be flush with the alarm housing (keys are enclosed with the
alarm in plastic wrapper).
To secure
To secure smoke alarm
smoke alarm to
to mounting plate and
mounting plate.
also secure back-up
battery.
CAUTION: Do not attempt to remove alarm or open battery
drawer without first removing locking key. If key is not first
removed, damage may result (see below).
17. Test alarm operation after installation in accordance with
"Operation: How to Test" instructions.
NOTE: Maximum interconnect wiring length is 150 feet (50
meters).
Outlet Box
MODEL SA379
120VAC Dual-Ionization
c/w 9VDC Battery Back-Up (Incl.)
Interconnectable
Smoke Alarm
SINGLE STATION
Smoke Alarm
MULTIPLE STATION
IMPORTANT: The SA379 is not interconnectable with any
other model produced by another manufacturer. The SA379 may
be interconnected only with the following UL listed smoke alarm
models:
American Sensors
American Sensors
American Sensors
ASI Electronics (American Sensors)
ASI Electronics (American Sensors)
Dicon Safety Products Inc.
Dicon Safety Products Inc.
Dicon Safety Products Inc.
0
F
0
C).
Note: This equipment should be installed in accordance with the
National Fire Protection Association Standard 72. (National Fire
Protection Association, Batterymarch Park, Quincy, MA02269).
To Remove Locking Key
To remove the locking key, insert a small screwdriver into the
small hole at the top of the battery drawer. Apply pressure at the
tip of the screwdriver, pushing up on the locking key. The
locking key will pop out.
To Activate the Alarm-Pause
®
Feature
Simply press the Alarm-Pause
®
button on the cover of the smoke
alarm for a minimum of 5 seconds then release to activate the
Alarm-Pause
®
feature. In this mode, the unit should not respond
to smoke (by sounding an alarm) for a period of approximately 10
minutes, unless the level of smoke concentration becomes very
heavy (approaching 4 per cent per foot obstruction). During the
Alarm-Pause
period, the smoke alarm should "beep"
®
approximately once every 45 seconds to alert the household that
the smoke alarm has been silenced.
Variations in Length of Alarm-Pause
®
Period
The Alarm-Pause
®
period will vary in length depending upon the
amount of smoke present. When there is no smoke, the Alarm-
Pause
®
will be activated for the longest period of time
(approximately six to ten minutes) after releasing the Alarm-
Pause
button.
®
If the level of smoke density increases, the length of the Alarm-
Pause
period will shorten. As the level of smoke density
®
approaches 4 per cent per foot obstruction (a very heavy
concentration of smoke), the smoke alarm will override the
Alarm-Pause
®
mode and sound an alarm. NOTE: If powered only
by battery, the level of battery voltage will also affect the length
of the Alarm-Pause
®
period. If the battery voltage is low, the
Alarm-Pause
®
will be activated for approximately 10 minutes. If
the battery voltage is high, the Alarm-Pause
®
will be activated for
a shorter period of time (approximately 4 minutes).
B. Operation: How to Test
Before Installation:
1. Connect battery. Ensure that the battery is correctly
installed. Positive terminal to positive contact and negative
terminal to negative contact, as indicated in the battery
drawer. Reversing the battery in the compartment should not
cause any damage to the smoke alarm. If the drawer is
pushed all the way in, a low battery beep will sound when
the AC power is applied after installation if the battery is
improperly installed.
Storage in low humidity, and certain transportation
conditions, may cause electrostatic charges to build up in the
alarm system housing. Although harmless, these charges may
increase the length of time during which the horn sounds
upon battery insertion or test button operation. The
condition may be cleared by gently wiping the outside of the
plastic cover with a clean, damp cloth.
2. Check that the red operating light flashes approximately
every 45 seconds.
3. Press and hold the test button until the alarm sounds. NOTE: It
may be necessary to press the test button for up to 20 seconds for
an alarm to sound. An alarm is indicated by 3 constantly
Smoke alarm
repeating beeps every 4 seconds, with the red LED flashing
intermittently . An alarm may continue to sound for up to 10
seconds after the button is released.
After Installation
1. Check to see that the green operating light is on. The
operating light is visible behind the slotted case and confirms
that the smoke alarm is receiving AC power.
2. At least once a week, press the test button until the alarm
sounds, then release.
NOTE: Multiple Station Only:
4. Test each alarm separately in the system.
5. Determine that the initiating alarm triggers other alarms in
the system.
7. BATTERY REPLACEMENT
The Eveready 216, 522, 1222, Duracell MN1604, MX1604 and
the Gold Peak 1604P are the only acceptable back-up batteries
for use in this smoke alarm. The back-up battery will power the
smoke alarm for at least one year under normal use. When the
back-up battery reaches the end of its normal life, a low battery
warning (intermittent beeping) for up to 30 days, will indicate
the need for back-up battery replacement.
NOTE: If the battery drawer is open, the low battery warning
beep is disabled. The battery drawer is designed to resist closing
when the back-up battery is removed, thereby ensuring visual
warning.
WARNING
!
Use of a non-recommended battery may be
detrimental to the proper functioning of the alarm.
8. MAINTENANCE & TROUBLESHOOTING
VACUUM EVERY SIX MONTHS
Your smoke alarm should be cleaned every six months to help
keep it working efficiently. REMOVE POWER TO ALARM.
Gently vacuum through the vents of the alarm with a soft brush
attachment. Keep vacuum nozzle from touching the unit.
RE-ESTABLISH POWER TO ALARM.
Problems are indicated by these events:
1. The alarm does not sound upon pressing the test button.
2. The green operating light does not remain steadily on when
BLACK
120VAC, 60Hz
WHITE
the unit is AC powered.
Cap Unused Wire
3. The red operating light remains steadily on or off (i.e. does
Twist Connectors
not flash once every 45 seconds, when the unit is not in
Ceiling
Mounting Plate
alarm).
Supplied Gasket Must Be
Installed In Mounting Plate
Try the following:
Quick Disconnect
Power Connector
1. Inspect breaker or use in power circuit to alarm.
BLACK
120VAC, 60Hz
WHITE
2. Check that the unit contains recommended battery type.
ORANGE interconnect
3. Check the battery is properly connected (Observe polarity).
4. Gently vacuum as recommended above.
5. Replace battery.
6. Call a trained, experienced serviceman to inspect house
wiring and connection to alarms.
If these procedures do not correct the problem, do NOT attempt
repairs. If the smoke alarm is within warranty period and terms,
indicate the nature of the problem and return the unit with proof
of purchase to the point of purchase, distributor or manufacturer.
See below for instructions. Units beyond warranty cannot be
economically repaired.
COS2010
FALSE ALARMS:
SA379
SA360
Model SA379: Press the Alarm-Pause
®
button to silence nuisance
ESA5010
alarms.
ESA5011
Abnormal air conditions may cause the highly sensitive smoke
670L
alarm to give a "false" alarm. If no fire is apparent, ventilate the
670LR
room and/or blow fresh air into the unit until the alarm stops.
370LBX
Once cleared, the smoke alarm will automatically reset.
DO NOT DISCONNECT THE AC POWER OR THE BACK-
UP BATTERY
Dust can lead to excess sensitivity. Vacuum as recommended
above.
9. LIMITED WARRANTY
Your American Sensors SA379 Smoke Alarm, excluding the
battery is warranted for ten years from the date of purchase
against defect in material and workmanship. Units returned to
Dicon Global Inc. with proof of purchase date
during this period as a result of such defects will be repaired, or
replaced at Dicon Global Inc.'s option.
This warranty only covers defects in material or
workmanship in normal residential use and does not cover the
battery, nor does this warranty cover damage resulting from
negligent handling, misuse, or lack of reasonable care. This
warranty is in lieu of any other warranty either expressed or
implied.
DICON GLOBAL INC. SHALL HAVE NO
LIABILITY FOR ANY PERSONAL INJURY OR PROPERTY
DAMAGE, OR ANY SPECIAL INCIDENTAL,
CONTINGENT OR CONSEQUENTIAL DAMAGE OF ANY
KIND RESULTING FROM A FIRE. THE EXCLUSIVE
REMEDY FOR BREACH OF THE LIMITED WARRANTY
CONTAINED HEREIN IS THE REPAIR OR REPLACEMENT
OF THE DEFECTIVE PRODUCT AT DICON GLOBAL
INC.'S OPTION. IN NO CASE SHALL
DICON GLOBAL INC.'S LIABILITY
UNDER ANY OTHER REMEDY PRESCRIBED BY LAW
EXCEED THE PURCHASE PRICE. YOUR SMOKE ALARM
IS NOT A SUBSTITUTE FOR PROPERTY, DISABILITY, LIFE
OR OTHER INSURANCE OF ANY KIND. APPROPRIATE
COVERAGE IS YOUR RESPONSIBILITY. CONSULT YOUR
INSURANCE AGENT.
This warranty gives you specific legal rights and you may also
have other rights which vary from province to province.
Units may be returned to point of purchase according to
retailers exchange / return policy. Or call 1-800-387-4219, for
shipping instructions and a returned goods authorization number
"RGA" number, to return to Dicon Global Inc.
Returned goods must be shipped prepaid. A cheque for $5.00 is
also required for return postage. Please mark the "RGA" number on
the exterior of your package. Date code located on back of smoke
alarm.
Dicon Global Inc.
20 Steelcase Road West, Unit 3
Markham, Ontario,
Canada L3R 1B2
email: [email protected]
10. AMERICAN SENSORS PRODUCTS
AMERICAN SENSORS SMOKE ALARMS
American Sensors offers a complete line of smoke alarms. Select
from this group of quality products to ensure your home is fully
protected in case of fire.
Smoke Alarm
Model
Description
Power Source
Technology
Ionization
SA310
Basic Model
9V Battery
General Purpose Model
SA320
9V Battery
Ionization
with Alarm-Pause
®
Feature
Hall and Stairways Model
Ionization
SA358
2-9V Batteries
with Emergency Light
Extended Life
Extended Life
SA500
Multi-Location with
Battery with
Ionization
Alarm-Pause
Model
3 Year Warranty
®
Long Life Multi-
Long Life Lithium
SA900
Ionization
battery with 10
Location with
Alarm-Pause
®
Model
year warranty
Professional Hardwire
SA360
120 Volt AC
Ionization
Multi-Location Model
Professional Hardwire
120 Volt AC with
with Battery Back-Up
SA379
9 Volt Back-Up
Ionization
and Alarm-Pause
®
Battery
Model
AMERICAN SENSORS
CARBON MONOXIDE ALARMS
American Sensors also offers a complete line of Carbon Monoxide
Alarms including :
CO800 -
Plug-In Carbon Monoxide Alarm
CO810 -
120 Volt AC Hardwire Carbon Monoxide Alarm
CO900 -
Plug-In Carbon Monoxide Alarm with Battery Back-
Up
CO910 -
Plug-In Carbon Monoxide Alarm with Digital LED
Display
CO920 -
Plug-In Carbon Monoxide Alarm with Digital LED
and Back-Up Power Source
CO1100 - Battery Powered Carbon Monoxide Alarm for Table
Top, Travel or Wall Mount
IONIZATION
SMOKE ALARM
with Battery Back-Up
SA379
MODEL
READ CAREFULLY AND SAVE.
This manual contains important information.
A copy of this manual must be left with the end user.
2502-2507 (REV-0)