Euro-Pro EP604H Instrukcja obsługi - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Odkurzacz Euro-Pro EP604H. Euro-Pro EP604H 6 stron. Retractable cord stick vac

Euro-Pro EP604H Instrukcja obsługi
OPERATING INSTRUCTIONS
Cleaning & Changing the Hepa-
Type Filter
PLEASE NOTE:
The white pleated
filter material in the HEPA-Type dust
cup filter will discolor over time -This
is NORMAL and will NOT affect the
performance of the filter. If the HEPA-
Type dust cup
filter is properly
"TapCleaned"
Fig. A
after each use
Wash once a
and suction
month or when
suction
does not return
appears
to 100%, then
reduced.
we suggest that
Warning:
Allow 24
the HEPA-Type
hours for air drying
filter be
before replacing in unit.
"TapCleaned"
vigorously until no
more dust can be removed, then
rinsed under the faucet and allowed to
air dry for 24 hours before refitting into
the vacuum. (Fig. A) Wash once a
month or when suction appears
reduced.
Re-Installing Dust Cup (Container)
1. Ensure that small air intake vent
on the dust cup is aligned with the
opening on the main unit. (Fig. 12)
2. Slide the dust cup container into
place and lower the dust cup
retainer handle.
3. Push retainer handle until you hear
it lock into place. (Fig. 13)
Air Intake
Vent
Fig. 12
Fig. 13
CAUTION
: The suction hole must be
open, free of any obstructions at all
times. Otherwise, the motor will
overheat and could become damaged.
Warning:
Always empty the dust cup
container and clean the HEPA-Type
filter before each use and during
prolonged usage.
Never over fill the dust cup (container) -
remove dirt and clean the HEPA-Type
filter when dirt in dust cup is at or below
the "MAX" level during prolonged usage
or risk motor damage.
If you wash the HEPA-Type filter,
make sure that it is completely air
dry before inserting back in the
vacuum.
Please Note: The HEPA-Type filter is
washable. It should, however, be
replaced every three (3) to six (6)
months, depending on usage to ensure
peak performance of your vacuum.
Motor Thermostat
Important:
This unit is equipped
with a motor protective thermostat. If
for some reason the vacuum cleaner
should overheat, the thermostat will
automatically turn the unit off. Should
this occur:
Push the On/Off button once.
Disconnect the plug from the
power source.
Check the source of overheating
problem. (i.e. clogged hose or
filter)
If clogged hose or filter is found,
unclog the hose and replace the
filters.
Wait at least 45 minutes before
attempting to reuse the vacuum.
After unit has cooled down for
45 minutes, plug in the cleaner
and push the On/Off button. The
vacuum should start again.
If the vacuum still does not start,
contact customer service at
1 (800) 798-7398.
6

PRECAUTIONARY MEASURES

IMPORTANT:
If the suction opening in the unit or the hose is BLOCKED, switch off
the vacuum cleaner and remove the blocking substance before you
start the unit again.
1. Do not operate the vacuum cleaner
too close to heaters or radiators.
2. Before inserting the power plug into
the wall outlet, make sure that your
hands are dry.
3. Before you start vacuuming, make
sure to remove large or sharp objects
that might cause damage to the unit.
4. When pulling out the power plug
from the wall outlet, pull the plug not
the power cord.
5. Do not pick up anything that is
burning or smoking such as
cigarettes, matches or hot ashes.
6. Do not vacuum any liquids.
7. Do not use without dust cup
(container) or HEPA-Type filter in
place.
Note:
This vacuum cleaner is equipped
with a plug and power cord that retract
automatically. If the cord or plug get
damaged, it must be replaced by a
qualified technician.
Warning:
Hold the plug when
rewinding the cord. Do not allow the
cord to whip when rewinding.
3