WARNING:
Do not install your dehumidifier in a corrosive environment. Some liquid va-
por barriers dry via "solvent evaporation". Always make sure that barrier is completely dry
and area is throughly ventilated before installing dehumidifier.
Step #1: Place dehumidifier on a level surface.
If the unit is handled in such a manner that the compressor did not remain in the up-
right position, it is necessary to place on a level surface and wait a minimum of 2 hours be-
fore turning the unit "on"
NOTE: XG90 Dehumidifiers can't sit directly on floor unless the unit is feeding directly
into a sump pump next to it. Elevation is required to allow gravity flow of condensate water
drain.
Step #2: Set Up Drain Line
The drain line should be routed to a suitable drain on the outside. It must flow down
to a drain without any loops, dips, or valleys.
Recommended Drain Option-Transition to PVC Pipe
1.
1. Cut a piece of 3/4" OD PVC that is approx. 6" long.
2.
2. Insert PVC into a 3/4" elbow, then attach to a 3/4" OD length of PVC to drain.
(Note: Keep the length of PVC drain pipe to a minimum)
3.
3. Insert the open end of the tubing into the 3/4" pipe so that it does not extend into
the elbow fitting. For proper flow, a minimum downward slope of 1" per 10' run is re-
quired. (Note: If a proper downward angle is not possible, then it is recommended to
use a Titan XP90 which includes an integrated condensate pump or utilize an exter-
nal condensate pump).
4.
4. Support the PVC tubing so that it maintains a smooth downward flow to drain.
5.
5. Always test the drain before leaving installation area.
Step #3: Plug unit into 15 amp grounded circuit.
6.
4