Przeglądaj online lub pobierz pdf Instrukcja montażu dla Kontrolery dostępu IP eKey integra Series. eKey integra Series 2 stron. For ekey finger scanner (fs); for ekey control panels (cp)

Wall-mounted (WM)
Installation
Open lid for electric
connection
a) To mount the ekey control panel
(1)
, please use the supplied screws and plastic dowels
Mark the drill holes
(4)
on the wall using the DIN rail
(3).
b) Drill two 5 mm wide holes and place the dowels into them. Afterwards, fasten the DIN rail using the corresponding screws.
c) Finally, clip the ekey CP WM onto the rail.
Alternatively, your ekey CP WM can be installed on the DIN rail (35 mm) in your electrical cabinet.
Make sure to leave enough space above (for opening) and below (for electric wiring) the CP!
DIN rail mounted (DRM)
Installation
a) A DIN rail according to DIN EN 55022 or DIN EN 60715 TH35 with 35 mm is suited best to install the ekey CP
(1)
(2)
DRM (multi)
.
You can therefore install the ekey CP DRM (multi) in your electrical cabinet.
(3).
b) Attach the upper part of the control panel on the DIN rail
c) Pull the latch
(4)
downward and place the lower part of the control panel on the DIN rail as well. Finally, release
the latch to fasten the control panel.
Make sure to leave enough space below the CP (for electric wiring)!
mini (mini)
Installation
a) To mount the ekey CP mini
(1)
, please use the supplied screw and plastic dowel.
Mark the drill hole
(4)
on the wall using the DIN rail
(3)
b) Drill a 5 mm wide hole and place the dowel into it.
c) Afterwards, fasten the DIN rail using the corresponding screw
d) Finally, clip the ekey CP mini onto the rail.
Alternatively, your ekey CP mini can be installed on the DIN rail (35 mm) in your electrical cabinet.
(2).
Technical Data
Power Supply
Power Input
Temperature Range
Dimensions
Interfaces
Relay
3)
Input
IP class
Programming
Display
max. wiring length of RS485 bus line (CLAMP 1,2)
max. wiring length of supply line (CLAMP 3,4,5,6)
when used in an industrial area
max. length of wires for relay and input (CLAMP 7-24)
when used in an industrial area
Dimensions
1)
Ohmic load exclusively
2)
When switching inductive and capacitive loads, adequate safety measures should be taken in order to protect the relay contacts (sparks
suppressor). The control panel does not have any built-in spark suppressors.
3)
Define low and high, at which resistance between Input 12C and Input1, respectively Input2 are recognized as low or high.
4)
When using the recommended cables
(2)
.
for ekey control panels (CP)
Technical Data
Description
Unit
VAC
Power Supply
VDC
Power Input
W
Relay
Amount
Relay Switching Capacity
A
mech. Relay Life Span
Operations
elec. Relay Life Span *
Operations
200.000 at 250V/5A
Temperature Range
°C
IP Class
IP
Digital Inputs
Dimensions
mm
W: 180 H: 110 D: 39,2
*The life span of the relay output decreases further when switching inductive or capacitive loads.
If you switch such loads, you have to take precautions on the relay output to avoid flying sparks.
There are no spark extinction elements built-in the ekey control panels!!
Description
Unit
VAC
VDC
W
°C
-20 up to +70
4HP acc. DIN 43880
max. Switching Voltage
1)
VAC / VDC
1)
max. Switching Current
AAC / ADC
Mechanical Life Span
Operations
1) 2)
Electric Life Span
Operations
Low
k
High
k
20 (to be mounted in the electric
IP
4 Push Buttons
1 LED for relays (green); 1 LED
for inputs (red), LCD 106x56
4)
m
m
m
mm
W: 70 (4HP) H: 86 D: 54
Technical Data
Description
Unit
Value
VAC
8-24
Power Supply
VDC
8-30
Power Input
W
ca.1
Relay
Amount
1
Relay Switching Capacity
42 VDC / 1 A
Temperature Range
°C
-20 up to +70
IP class
IP
20
Digital input
1
(only dry contact configurable!)
Dimensions
mm
W: 25 H: 60 D: 42
integra
ekey control panel for integration into door panels!
Value
9-12
9-12
ca. 1
1/3
230VAC/ 5A
10 Mill.
-20 up to +70
20
-
Value
8-24
8-24
ca. 1W
RS485
42
2
10 Mill.
100 000
<1
>50
cabinet)
Forend round
Forend square
cut
cut
500
Opening for cable feed
30
(the position of the opening can be higher or lower)
30
a) To mount the ekey CP IN
(2)
template
. Available milling width: 18, 20 or 24 mm
Pay attention to the control panel's shape of the forend.
(square / round)
b) To fasten the control panel, please use the
supplied screws.
c) Tighten the screws at the predefined holes at
top and bottom of your ekey CP IN
Technical Data
Description
Power Supply
Relay
Relay Switching Capacity
Peak AC
ON Resistor (max.)
Leakage Current
Boot time
Shut-off time
Temperature Range
IP class
Digital inputs
Maximum voltage on X6 Pin 1
(only applicable for integra)
Dimensions
(1)
in the door, please work it according to
(3)
.
Unit
Value
VAC
8-24
VDC
8-24 (max. 30V)
Amount
1 / 2
VAC (DC)
42 VDC (AC) / 2A
VAC (DC)
60
0,12
µA
1
ms
1,5
ms
0,5
°C
-40 up to + 85
IP
40 (front end)
Amount
1
A
3
W: 18/20/24,
mm
H: 272, D: 21