Da-Lite Cosmopolitan Electrol Instrukcja obsługi - Strona 5
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Tablica Da-Lite Cosmopolitan Electrol. Da-Lite Cosmopolitan Electrol 6 stron. For sizes up to 9'x12'
Również dla Da-Lite Cosmopolitan Electrol: Instrukcja obsługi (8 strony), Instrukcja obsługi (8 strony), Instrukcja obsługi (8 strony), Instrukcja obsługi (16 strony), Instrukcja obsługi (6 strony), Instrukcja obsługi (8 strony)
COSMOPOLIT N
®
ELECTROL
CONTROL
240V WIRING DIAGRAM
WITH OPTIONAL BUILT-IN
LOW VOLTAGE CONTROL
BLUE (COMMON)
BROWN (HOT)
240VAC 50HZ
GREEN
GROUND–MUST BE
CONNECTED TO
BUILDING GROUND
ILT RJ9 PIN-OUTS
(TAB IS FACING UP)
IR or UP
BLACK
GND COMMON
RED
+5V
GREEN
DN or DATA
WHITE
SCREEN DJUSTMENT FOR SCREENS WITH
1. Remove the cover plate from the 3-button wall switch and remove the switch from the junction box.
2. Locate small 3-position switch on back of wall switch. See Figure 4 for 120V screens or Figure 5 for
220/240V screens.
3. To adjust the down limit switch, slide the 3-position switch to the down position. Press and hold the down
button to run the screen down to the desired stop position. Release the button to stop the screen. DO
NOT PUSH THE STOP BUTTON.
4. When the screen is in the desired down position, slide the 3-position switch to the off (center) position.
The down limit switch is now set.
5. To adjust the up limit switch, slide the 3-position switch to the up position. Press and hold the up button
to run the screen up to the desired stop position. Release the button to stop the screen. DO NOT PUSH
THE STOP BUTTON.
6. When the screen is in the desired up position, slide the 3-position switch to the off (center) position. The
up limit switch is now set.
7. To test limit switch setting, make sure the 3-position switch is in the off (center) position. Press and
release the up or down button on the wall switch to operate the screen.
8. Replace switch and cover plate on the wall.
NOTE: If stop button is pressed, the wall switch will reverse direction. To correct this, press the stop button
again. This will reset the switch. You will have to re-set both the up and the down settings.
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit switch adjustments, EVEN if a third party
control system is used. Therefore, it is advised to wire the switch or provide a 4-conductor
connection that is accessible.
®
INST LL TION FOR SCREENS WITH
MOTOR
GREEN
GROUND TO CASE
IMPORTANT NOTE: The wall switch is REQUIRED to make any limit
BUILT-IN LOW VOLT GE CONTROL
BUILT-IN LOW VOLT GE
OPTIONAL IR AND RF
REMOTE CONTROL
RJ9
RJ9
SPLITTER
DRY CONTACTS
switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire
the switch or provide a 4-conductor connection
that is accessible.
4
LOW-VOLTAGE WALL SWITCH
UP DN
GND +5V
UP
STOP
DOWN
3-POSITION
RJ9
SWITCH
FRONT
BACK
FIGURE 5