Technical data ekey home
Power supply
Power input
Relays
Switching capacity of the relays
Mechanical life span of the relays
Electrical life span of the relay *
Temperature range
Protection class
Digital inputs
*The electrical life time will be reduced further by switching capacitive or inductive appliances. If you want to switch such appliances place electric spark compression units to
protect the releais-contacts.
Technical
integra control unit
Power supply
Power input
Relays
Switching capacity of the relays
RELAIS
Switching power
Load voltage(Peak AC)
ON resistance (max.)
OFF state leackage current
Turn On time
Turn Off time
Temperature range
Protection class
Digital inputs
Maximum current to X6 PIN 1 (only
with Integra)*
*
A maximum of 3.5A can be output via X6. E.g. if 2.8A are consumed via X6PIN1, then only a maximum of 0.7A can be used by X6PIN1.
The control panel and the finger scanner have to be connected with a 4-core cable which has a minimum diameter of
0.5 mm (equals a 0.14 mm² core diameter). For distances of over 50m a cable with a larger core diameter has to be
selected for the live cores (connections 3 and 4). The maximum length of cable between the finger scanner and the
control panel is 500m.
1 relay is available (3 relays in the ekey home 3 and pc versions) for controlling external devices. Its programming is
carried out via the programming menu. The relay has a change-over contact, which can be used as required - the
maximum switching capacity is 250VAC 5A (with the integra version 30V / 2A). Every single door lock must, without
exception, be connected to a separate power supply (do not use the supplied power adaptor!).
The connecting cable between the control panel and the finger scanner has to be laid separately from the electric
installations of the building, as these signals produce a low-voltage area, which can be impaired by neighbouring live
cables.
The connections are not protected against reverse polarity!
Version 1 : 6.2.09 BRUM
control panel
data
ekey
home
Unit
ekey home
V A/C
9-12
V D/C
9-12
W
approx. 2
Number
1
230V AC / 5A
Switching cycles
10 mill.
Switching cycles
200,000
250V/5A
°C
-20 to +70
IP
40
-
Unit
ekey home integra
VAC
8-24
VDC
8-30
W
approx. 1
Number
1
30V D/C / 2A
42VDC(AC)/2A
V
60
0,12
A
1
ms
1.5
ms
0.5
°C
-40 to +85
IP
40 (front)
1
A
3
ekey home 3, pc
ekey net
9-12
9-12
approx.2
3
230V AC / 5A
10 mill.
at
200,000 at 250V/5A
-20 to +70
40
-
ekey home integra 2,
pc
8-24
8-30
approx. 1
2
30V D/C / 2A
42VDC(AC)/2A
60
0,12
1
1.5
0.5
-40 to +85
40(front)
1
3