Channel list, Frequency converter, F-channels
No.
Name
F001
Communication with frequency converter
0
Communication disabled
1
Communication activated
F002
Acceleration time from closed position
motor 1 and 2 (from 0-100Hz)
F003
Acceleration time in all movements except at
closed position motor 1 and 2 (from 0-100Hz)
F004
Acceleration time when P500 is set to 2 and the
input is activated, battery backup
F005
Retardation time with limit switch and change of
direction for motor 1 and 2 (from 100-0Hz)
F006
Retardation time with photocell and vehicle loops
for motor 1 and 2 (from 100-0Hz)
F008
Low-speed frequency for opening movement,
motor 1 and 2
F009
Low-speed frequency for closing movement,
motor 1 and 2
F012
Opening frequency / Opening speed for motor 1
F013
Closing frequency / Closing speed for motor 1
F014 *
Number of degrees with low-speed frequency
before open position for motor 1
F015 *
Number of degrees with low-speed frequency
before closed position for motor 1
F022
Opening frequency / Opening speed for motor 2
F023
Closing frequency / Closing speed for motor 2
F024 *
Number of degrees with low-speed frequency
before open position for motor 2
F025 *
Number of degrees with low-speed frequency
before closed position for motor 2
* = Shown only when L001 and/or L002 are set to 1 encoder or 4, hold-to-run without limit switch.
F-channels are shown only when C2020=4, frequency converter.
10
10
DAAB INTERFACE CARD DB409 INSTRUCTION MANUAL
Range
Factory Setting
0 - 1
1
0.5-9.9 seconds
2.0
0.5-9.9 seconds
4.0
5.0-12.0 seconds
7.0
0.5-9.9 seconds
4.0
0.5-9.9 seconds
2.0
5-20 Hz
5
5-20 Hz
10
21-99 Hz
50
21-99 Hz
30
0-60 degrees
0
0-60 degrees
0
21-99 Hz
50
21-99 Hz
30
0-60 degrees
0
0-60 degrees
0