American Standard ACONT203AS42MA Instrukcja instalacji i obsługi - Strona 3

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Termostat American Standard ACONT203AS42MA. American Standard ACONT203AS42MA 20 stron.

American Standard ACONT203AS42MA Instrukcja instalacji i obsługi
2.

Product Specifications

Shipping Temperature Range
Indoor Temperature Display Range
Heat (Conventional Gas/Oil/Electric or HP Aux)
Central Air (Cool ) or HP (Heat/Cool)
Thermostat Configuration Options
Single Stage 1 No Heat Pump
Multi Stage 2 No Heat Pump
Heat Pump 1
Single Stage Compressor Heat Pump
Heat Pump 2
Two Stage or Two Compressor Heat Pump
*On every application, 24VAC loads should be reviewed to be sure the indoor unit control power transformer is adequately sized.
NOTE: Use 18-gauge color-coded thermostat cable for proper wiring. Shielded cable is not typically required.
Keep this wiring at least one foot away from large inductive loads such as Electronic Air Cleaners, motors, line starters, lighting ballasts and
large distribution panels. Failure to follow these wiring practices may introduce electrical interference (noise) which can cause erratic system
operation.
All unused thermostat wire to be grounded at indoor unit chassis ground only. Shielded cable may be required if the above wiring guidelines
cannot be met. Ground only one end of the shield to the system chassis.
3.

General Information

3.1

Overview

The 203 is a programmable push button thermostat with
a 3.5'' backlit display. The 203 features a scheduling mode
that can operate a 7-day program, 5-1-1 program or operate
in a non-programmable mode.
3.2

Contents

— 1-Thermostat
— 1-Sub-base
— 2-Phillips slotted head mounting screws
— 2-Nylon Drywall Anchors
— 1-Installation Guide / User Guide
3.3

Accessories

Wall Cover Plate (BAYCOVR200A)
Pub. No.
11-HD19D1-1D-EN
SPECIFICATION DESCRIPTION
Product Models
Product
Size
Configurations
Maximum Number of Stages
Operating Temperature
Input Power (DC)
Input Power (AC)
Terminal Load
Wire Usage
System Modes
Fan Modes
RATED DIFFERENTIALS
THERMOSTAT APPLICATION GUIDE
09/2020
Part No. 37-7777006
American Standard 203 Programmable Thermostat
ACONT 203
203
3-3/4" x 6" x 1-1/8" (HxWxD)
Heat Pump, Heat/Cool, Dual Fuel, Dual Fuel Low Unrestricted Mode Only
4 Stages Heat, 2 Stages Cooling
32°F to 105°F (0 to +41°C) / 90% RH Non Condensing
-20 to 150°F (-29 to +65°C)
Two 1.5V AA Alkaline
20-30 VAC, NEC Class ll, 50/60 HZ
1.5A per terminal, 2.5A maximum all terminals combined
18 AWG
Auto, Heating, Cooling, Off, Emergency Heat
Auto, On, Program
32°F to 99°F
Fast
0.5°F
0.9°F
Thermostat Applications
Gas, Oil, Electric, Heat Only, Cool Only or
Heat/Cool Systems, 2 or 3 wire Hydronic
Zone (Hot Water or Steam) Systems, 24 Volt
or Millivolt
Single Stage Compressor Heat Pump
Systems - up to 2 Stages Aux./Emergency
Heat
Two Stage or Two Compressor Heat Pump
systems - up to 2 Stages Aux./Emergency
Heat
4.

Installation

4.1

Location

The 203 is designed for installation in climate controlled living
spaces. Place the unit in a central location with good circulation.
For proper temperature sensing, avoid exposing the 203 to heat
radiated from lamps, sun light, fireplaces or any other radiant heat
source.
Avoid locations close to windows, behind doors or alcoves with
poor air circulation, adjoining outside walls, or doors that lead to
the outside.
Select a location that prevents the 203 from being directly exposed
to air currents from supply registers or ceiling fans.
Mount the Control on a section of interior wall that does not
contain hot or cold water pipes or duct work.
Medium
Slow
0.75°F
1.9°F
1.2°F
1.7°F
Maximum Stages Heat/Cool
1+1
2+2
3+1
4+2
3