Astivita DRV7KGWH Instrukcja obsługi - Strona 10

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Suszarka Astivita DRV7KGWH. Astivita DRV7KGWH 10 stron.

MAINTENANCES
The sound of dryer when runs can cause
Due to heavy wet clothes' turning and bumping, and
this will cause noise accordingly.
Air bumping: When drying, machine will generate steam which will come
out from pipe and this will cost bumping with the bottom of inner tub.
Error
description
Criteria
code
Over-temperature
E1
NTC or PCB fault
Temperature Sensor
Temperature
E3
is open or PCB fault
Sensor error
Temperature
Temperature Sensor
E4
Sensor error
is short or PCB fault

Technical Specifications

Model
DRV7KGWH
Dimension
555*595*840(mm)
(L*W*H)
Rated input power
2000W
Rated voltage
220-240V~
Rated frequency
50Hz
Weight of product
35kg
Rated capacity
7.0kg
Ambient temperature
+5°c~+35 c °
Note!
The rated capacity is the maximum capacity, make sure that the dry clothes
which are loaded to the appliance do not exceed the rated capacity each time.
• Do not install the tumble dryer in a room which the temperature around freezing
point, and will have a risk of frost occurring, the tumble dryer may not be able
to operate well.
Action after fault
Failure indication
debounced
Stop the program
Led less flashing
and go to fault
state
Stop the program
Led less and
and go to fault
standard flashing
state
Stop the program
Led extra flashing
and go to fault
state