Dontek AQUASMART 5 SV Instrukcja obsługi - Strona 11
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Kontroler Dontek AQUASMART 5 SV. Dontek AQUASMART 5 SV 13 stron.
TROUBLE SHOOTING CONTINUED
POOL NOT HEATING:
If the controller has stopped pumping and is displaying a higher temperature than expected it may be caused by a
pump which is failing to prime. Check the pump and if necessary, prime the pump as per the pump manufacturers'
instructions then reset the controller by turning it off/on.
Check the controller LCD screen to see if any sensor faults are present and fix as required.
Check to see if the error message "Circulation Pump Failed to Prime" appears. If so either reset the Pump Load
Settings (refer to Prime Protection settings in the Installer Setup menu), or disable the Prime Protection feature (refer
to Prime Protection settings in the Installer Setup menu).
If the controller is in Standby Mode, the controller won't heat the pool using solar heating, no matter what the roof
temperature is. If it is consistently warm enough, switch the controller back into Heating Mode to start heating your
pool.
Check the controller settings to ensure that the AUX temperature and runtime settings are correct.
Check and ensure that the Heater Interlock cable is connected to the plug properly and that the plug is pushed in.
Check and make sure that the heater has power connected.
Check and ensure that the Heater Interlock cable is connected to the appropriate position inside the heater,
according to the heater manufacturer's instructions.
VALVE ACTUATOR NOT TURNING:
Check and ensure that the wires are screwed into the plug properly and in the correct order (Red, Black, White, from
left to right with the screws of the plug facing upwards towards you).
Check and ensure that the plug is pushed into the Valve socket properly.
Check and ensure that the toggle switch of the actuator is in either of the ON positions and not in the middle OFF
position.
Check the settings of the controller to ensure that the Solar is not turned off, controller is not in 'Auto Standby
Mode', and that both sensors are ready.
Make sure that the valve can be turned manually to ensure that the valve isn't jammed (debris inside the valve, or
valve actuator seized/not working).
If the above all checks out, then you controller needs repair.
FACTORY
RESET:
Hold down ENTER when power is off, hold down after powering up, releasing after 5 seconds.
Dontek Electronics Pty Ltd
PO Box 239, Bayswater VIC 3153 Australia
Phone: +613 9762 8800 Email: [email protected]
11
AQUASMART 5 SV v1.4