Amerisolar Wolfram-BAT-10.24 Instrukcja instalacji - Strona 5
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Akcesoria do kamer Amerisolar Wolfram-BAT-10.24. Amerisolar Wolfram-BAT-10.24 20 stron.
Worldwide Energy and Manufacturing USA Co., Limited
M6*12 pan
10
headcombination
screw
11
2.2 Transport Requirement
During transportation, the battery packaging box must be placed horizontally, and avoid
strong vibration, shock and heavy pressure during transportation.
2.3 Storage Requirements
If the battery system is not put into operation immediately, it needs to be stored under specific
environmental conditions. Amerisolar is not responsible for any failure caused by storage.
When storing, ensure that the power of the battery system is not less than 60%; the storage
environment temperature should not exceed 40°C, and the relative humidity should not
exceed 80%. At the same time, it should be kept away from flammable and explosive
materials, dust and metal powder, and acid or other corrosive gases. The battery system
should be stored in a place away from rain, humidity and sunlight.
3. Product Description
The Wolfram-BAT-10.24 residential energy storage system product is made of lithium iron
phosphate batteries and has the characteristics of long life, stable performance, and high
charge and discharge efficiency. Two built-in independent battery systems are connected in
parallel and output through two 2P circuit breakers.
3.1 Precautions
3.1.1 Identification Definition
File
Table 3.identification definition
Be careful, risk of electric shock
Ignoring safety warnings or improper operation may cause minor
injuries or minor or moderate damage to equipment or property
Do not short-circuit the battery
/
3
12
1