TESTING THE KEYPAD

1. Connect the positive (=) lead of your 5 or 12VDC
power supply from the control panel to the terminal
(TS1) =V input.
2. Connect the negative (-) lead of your 5 or 12VDC
power supply from the control panel to the terminal strip
(TS1) -V input.
3. Turn on power supply.
4. Enter Self Test Mode: Press 7890#123456*. The
leds will light sequentially, and the sounder will beep 3
times. This tests all 12 keys on the keypad, and veri-
fies proper circuit functioning.
NOTE:
The keypad may be programmed in your shop or at the
installation site. Programmed information is stored in
non-volatile so it will not be lost.
WIEGAND SERIES
DEFAULTS
The DoorwGard Wiegand Series keypads are
designed for easy installation in a minimum amount of
time. The following defaults have been factory pro-
grammed.
Master Code (user 1)
Standard Options:
Sounder keypress feedback:
Auto-Entry:(no * key required)
System Options:
Yellow LED feedback on keypress:
Red LED :
Red LED activates when line is pulled:
Green LED:
Green LED activates when line is pulled:
Wiegand format:
If defaults must be changed or additional functions are
desired, please refer to the PROGRAMMING
OPTIONS chart after you are familiar with the
PROGRAMMING section.
2
PROGRAMMING
1. Enter programming mode
Press 99 # (master code ) *
or press sw1 switch
2. To change master code
Press
Press (new master code) *
3. Exit programming mode
Press *
NOTES:
1
The Wiegand series DoorwGards are factory pro-
grammed with a master code of 1234 *.
2
Some DoorwGard products contain a sounder in
place of the yellow LED. In these products the
flashing is replaced by a beeping.
3
The master code is always user 1.
• The master code allows access to the
programming mode.
• All codes must be followed by the *.
• Master code may be from 1-6 digits in length,
and digits may be repeated.
• If the master code is forgotten or does not
seem to be working, momentarily push SW1
to enter programming mode and begin at step 2
above (see wiring diagram for location).
1234 *
• If the yellow LED lights solid while in program
ming mode an error has occurred. Press * to clear
ON
(yellow LED should flash) and start over from
step 2 or 3 above.
OFF
• Access code programming is done at the control
panel
ON
• If LED does not change states, a " pull-up "
Enabled
resistor may be required. Using a 10kΩ ¼w
Low
resistor, connect one end to V+ @ the control
Enabled
panel and to Led @ the control panel.
• All Wiegand control panels are not the same,
High
Contact IEI for an updated list of qualified Wiegand
26 bit
panels that have been tested and are known to be
compatible with IEI's Wiegand 272 series keypads.
1
3
1 # (new master code) * Flashes fast
6057130 REV 1.1
2
Yellow LED
Flashes slowly
Flashes slowly
Out