2. OPERATION MODE
By successive pushing the remote control unit button or
switch button, the control unit will execute a series of step con­
trol commands (opening — stop — closing — stop).
Execution of the commands is shown by indicators Up and
Down. Programming shall be made in standby mode when only
the PWR indicator is on. The PWR indicator is on when the con­
trol unit is energized. Button P is used for adjustment of remote
control units for DoorHan receiver.
DESCRIPTION OF OPERATION MODES
Mode 1 is used to control an electric lock by impulse control
signal (2 sec). This mode also realizes "operator presence
mode" after the continuous control signal is given, for exam­
ple, when the button is pressed and held down — the door
leaf moves, when the button is released — the leaf stops.
Modes 2 and 3 with long signal (70–90 sec) are used to
control tubular motors of all types.
Mode 4 is used to control indoor lighting from the switch
and (or) the remote control unit.
OPERATION MODE ADJUSTMENT
Press button T for 2 sec and release 1, 2, 3 or 4 times to
select the desired control mode having guided by the indicator
Up flashing:
Up indicator flashes 1 time — the motor will stop in 2 sec.
Up indicator flashes 2 times — the motor will stop in 70 sec
(default setting).
Up indicator flashes 3 times — the motor will stop in 90 sec.
Up indicator flashes 4 times — the motor will not stop (to
control lighting or other devices remotely or stationary).
DOORHAN REMOTE CONTROL UNIT ENCODING
In standby mode press the button P and hold it down until
the Dwn indicator starts flashing (1–2 sec), after that press the
necessary button on the remote control unit for 1–2 sec.
CODE DELETION
In standby mode press the button P and hold it down until
the Dwn indicator is on and then off (10–12 sec).
We appreciate very much that you have chosen the product manufactured by our company and are confident that you will be sat­
isfied with the quality. For information on purchasing, distribution and servicing contact DoorHan regional offices or central office:
DoorHan, 120 Novaya Street, Odintsovo District, Akulovo, Moscow Region, Russia, 143002
Tel.: +7 (495) 933-24-33 | www.doorhan.ru | e-mail: [email protected]
5. Wiring
Contact function (Fig. 1 and 2)
1. Supply mains neutral ~220 V
2. Supply mains phase ~220 V
3, 4. Connector for jumper (if required)
5. Direction A of operator (black wire)
6. Common (blue) wire of the operator (neutral)
7. Direction B of operator (brown wire)
8. Direction B of switch
9. Common wire of switch
10. Direction A of switch
11. –12 V power of external radio receiver
12. +12 V power of external receiver
13, 14. Connection NO control contacts of external radio re­
ceiver or key­switch.
6. Safety Instructions
1. Have only trained personnel carry out installation and main­
tenance of the control unit in accordance with the safety in­
structions.
2. Do not mount the control unit close to heaters. Distance be­
tween the control unit and a heater shall be more than 1 m.
3. In case of faulty operation of the control unit, disconnect the
control unit from the mains and contact the support service
specialist.