QUICKSTART "BASIC" GUIDELINES FOR MODEL 1175 - DIP-SWITCH AND WIRING REFERENCE
SW 1 DIP-Switches
Switch
Function
Setting
Opening
1
MUST be in ON Position.
Direction
2
OFF
Leave in OFF Position.
The output wired to terminal #4 becomes the output from the exit loop detector
Exit Loop Port
OFF
3
Output
plugged into the EXIT Loop port.
Full Open Input
Normal Setting. Terminal #4 is a normal full open input.
ON
OFF
Auto-close timer is OFF. Manual input required to close gate/door.
Auto-Close
4
Timer
ON
Normal Setting. Auto-close timer is ON. Adjustable from 1-23 seconds.
5
OFF
Leave in OFF Position.
SW 1
6
OFF
Leave in OFF Position.
Normal Setting. Relay activates when gate/door is at open limit.
7-OFF
8-OFF
Circuit
Relay activates when gate/door is not closed.
7-OFF
8-ON
Board
7 and 8
Relay activates when gate/door is opening and open.
7-ON
8-OFF
Relay
Relay activates during opening and closing cycle.
7-ON
8-ON
SW 2 DIP-Switches
Switch
Function
Setting
1
Leave in OFF Position.
OFF
Normal Setting. Magnetic lock is not used.
OFF
2
Magnetic lock
Magnetic lock is used and connected to terminals 9 and 13
ON
3
SW 2
ON
Switch 3 MUST be in ON Position.
4
OFF
Switch 4 MUST be turned OFF for Model 1175 operator.
Installation of ONE EXTERNAL entrapment protection MONITORED device
MUST be installed in the DOWN direction or operator WILL NOT function.
IMPORTANT:
Photo sensors must use Normally Closed (NC) contacts
with the beam set for light operate (relay activated when beam is not
obstructed). Some manufacturer's photo sensor contacts are labeled as
Normally Open (NO) but their relay functions the same way as described
above. See specific manufacturer's wiring manual for more information
about their specific relay function.
ONLY connect monitored devices.
ON
UL 325 DIP-Switches
MUST be turned ON for
each connected device.
1
2 3 4
Monitored Device Note: Only 1 monitored
Device can be connected to each input. An
OPTIONAL Expansion Board (sold separately)
will allow connection for additional devices.
SW 1 (Top 8 Switches)
Description
Note: After a DIP-switch setting is changed, power must be turned
OFF and then turned back on for the new setting to take affect.
SW 2 (Bottom 4 Switches)
Description
Non-Contact Sensor (Type B1)
Typical Vehicles (Single Beam)
Contact Sensor (Type B2)
Avoid interference with gate/door hardware.
Model 1175 is intended for installation only on overhead gate/doors used for vehicles.
Pedestrians must be supplied with a separate access opening.
For safety and installation instructions, please refer to the owner's manual.
Fire Dept Open
Gate will ONLY OPEN when this device is activated by authorized personnel ONLY (fire, police, EMS)
and operator has power. Alarm will sound during entire open cycle. Operator will then go into a hard
shutdown once fully opened. Operator MUST be reset to function normally again. This device MUST
be mounted in the line-of-site of gate so authorized personnel can monitor gate movement.
Activation Note: Activation of this device will OPEN gate regardless of the status of the open
direction monitored external entrapment protection device(s). If gate is opening, and the operator's
inherent entrapment
protection system detects an
obstruction, the operator will
reverse approx. 2 inches and
go into a hard shutdown.
Operator reset button MUST
be pushed to function again
OR cycle operator's power.
Supplied
Wire Harness
P2
FIRE
EXIT
LOOP
UL 325 DIP-Switches
Entrapment
Protection
POWER
Board
Close Beam
TIME
DELAY
Close Edge
REV SENSE
REV SENSE
SECONDARY
PRIMARY
REVERSE
LOOP
Junction
Box
4405-018
4-Pin Non-Removable Terminal
3-Button Control Station MUST be at least 5 ft above the
WARNING
!
AVERTISSEMENT
floor and 6 ft away from gate/door in the line-of-sight of
!
the moving gate/door. Warning label is required to be
Moving Gate Has the Potential of Inflicting Injury
or Death – Do Not Start Gate Unless Path is
Clear.
located next to the control station. See manual for more
La Porte Mobile a le Potentiel D'infliger Des
Blessures ou de la Mort - Ne Pas Démarrer la
information.
Porte à Moins que le Chemin ne Soit Clair.
Normally Closed Interlock Switch
3-Button Control Station
Operator Cycling
3-Pin With
Use a standard 4-wire 3-button
Jumper
N.C.
control station. DoorKing's
3-wire 3-button control station
Note: When
N.O.
CANNOT be used.
using 3-button
control station
#1 Open N.O.
Operator Stopped
AND interlock
Place jumper
E N
O P
switch together,
N.C.
on bottom
#2 Close N.O.
2 pins when
#3 terminal
S E
C L O
using 4-pin
(N.C.) must be
N.O.
#3 Stop N.C.
terminal.
wired in series.
O P
S T
#4 Com
To #3 Stop N.C.
To #4 Com
1
Com
Radio
2
Open
2
3
24VAC
Terminal #3 Note:
1
Exceeding 250 mA of power from this terminal
2
4
may cause the circuit board transformer to
3
overheat, causing intermittent problems.
4
4
Access
#5 Normally Open
5
Device
1477-010
Open
SW1
ON
5
6
Std
1
2 3 4
Type of wiring to be used on ALL external
Reverse
6
devices:
Gate
7
A) Type CL2, CL2P, CL2R, or CL2X.
Tracker
OB
7
B) Other cable with equivalent or better
8
Gate
CB
electrical, mechanical, and flammability
Tracker
8
ratings.
OE
#9 Normally Close
9
CE
24VDC
G
10
G
UL 325 Terminal
NC
N N
NO
11
12
Com
13
Com
24 Volt
1 amp max.
14
15
16
Q u
a d
S h
o w
17
18
19
20
-
Gate Tracker
DoorKing Access Control System (Model 1833,
20
1835, 1837 or 1838) tracker system can be connected. This
system can keep track of gate operator cycle count, shorted
inputs, loop detector problems, any forced entry attempts, if the
20-Pin Main
gate has struck anything during the open or close cycle, power
interruptions, etc. For more detailed information refer to the
Terminal
Tracker Installation and Wiring Manual, DoorKing P/N 2358-065.
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
Important:
Controls intended for
user activation must be located at
least six (6) feet away from any
moving part of the gate/door and
where the user is prevented from
reaching over, under, around or
through the gate/door to operate the
controls. Emergency access controls
only accessible by authorized
personnel (e.g., fire, police, EMS)
may be placed at any location in the
line-of-sight of the gate/door.
Com
Lock Engaged
Relay Com
24 Volt Com
Com
Relay N.O.
24 Volt - 250 mA max.
4-Wire
Lock Disengaged
Radio Receivers
Com
Relay Com
24 Volt - 250 mA max.
3-Wire
#5 - Access Control
Devices
Telephone
Entry
Stand-Alone
Key Switch
Magnetic Lock
Power (24-Volt DC) and logic
Stand-Alone
output. Power is shut off .5 sec.
Keypad
prior to gate starting and
remains off while gate is
opening and in the
open position.
Stand-Alone
Push Button
B o
SW 2, switch 2 ON.
x
n
SW 2
Stand-Alone
Card Reader
Note: All stand-alone
and telephone entry devices
must use a separate power
source.