DACE LUX DC12 Instrukcja instalacji i obsługi - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Otwieracz drzwi garażowych DACE LUX DC12. DACE LUX DC12 12 stron.

2.
Safety Beams
Safety Beams are used for the early detec on of an object obstruc ng the closing door that could result in
damage or injury. While Safety Beams will detect most obstruc ons including cars, people and pets, it may not
necessarily detect all obstacles but will greatly reduce the risk. It is highly recommended that Safety Beams are
fi ed when automa ng a garage door.
For the purposes of the wiring diagram DuraOp cs Wireless Safety Beams (code DOPT03) are shown.
Refer to 'Enable or Disable Safety Beams....Menu 3' for programming.
LIMITS
REV
AUX LOCK 12V TRIG INF GND
3.
Electric and Magne c Locks
An automated door must not be locked using a padlock as both the door and the operator could be damaged
should the operator be triggered while the door is locked.
If extra security is required the door can be locked using either an Electric Lock (strike lock) or a Magne c Lock
(power lock) and controlled by the operator.
Refer to 'Enable or Disable Electric/Magne c Lock....Menu 6' for programming.
+ve
Electric Lock
NO
Operator
Ba ery
COM
-ve
+ve
Magne c Lock
NO
External
Power
COM
Supply
-ve
A er connec ng the lock, it is important to select the correct lock type in the operator's Programming Menu,
as selec ng the wrong lock type may cause damage to the lock or cause the lock to func on incorrectly.
PL - Magne c / Power Lock
EL - Electric / Strike Lock
Cau on:
When fi ng a Magne c Lock to the door, no NOT use the power from the operator as the lock will drain the
operator's ba ery power.
Only use an external source to power the Magne c Lock.
LUX DC12
Control Board
Power
Input
DuraOp cs Wireless
Safety Beams
12V/
24V
GND
COM
NC
NO
FET
LUX DC12
Control Board
LIMITS
REV
AUX LOCK 12V TRIG INF GND
DACE
OR
Relay Module
Code: SA001
DACE
Relay Module
Code: SA001
20
Transformer Input Voltage
Board Input Supply
Motor Voltage
Motor Power (Rated)
Maximum Holding Capacity
Maximum Push/Pull Force
Ba ery
Maximum Daily Opera ons
(or in standby *)
* Opera ons in standby is dependent on
charge level of ba ery and dura on of
power loss.
The number of opera ons is calculated
using a 12V 5Ah ba ery. Using a bigger
Ah rated ba ery will increase the
opera ons in standby and standby
dura on but will not allow for more daily
opera ons.
Maximum Door Size
Travel Speed
Note: Travel speed is dependent on load
and ba ery voltage.
Outputs
Power
Input
Inputs
Features
TECHNICAL SPECIFICATIONS
220 - 240V AC @50Hz
Output Voltage: 16VAC
12 - 18V AC or 17 - 22V DC
12V
150W
1200N
50kgF
12V DC
Push/Pull Force
Opera ons (Cycles)
10kgF
110 (55)
20kgF
86 (43)
30kgF
62 (31)
40kgF
40 (20)
50kgF
16 (8)
Opera ons: either Open or Close
Cycles: both Open and Close
15m
2
8.5m/min
Auxiliary: Adjustable to be either a light, trigger, status or low
ba ery indicator.
Lock:
Adjustable to func on with either an electric or
magne c lock.
External Trigger and Beams
Programmable Limits
Adjustable Force Se ngs
Infrared Beam Input
Lock Output
Auxiliary Output: Light,
Trigger Input
Trigger, Door Status or
Ba ery Status
Holiday Lockout
Single Remote Erase
Up to 64 Programmable
Remote Bu ons can be set to
Remotes
ac vate the light or lockout
func ons individually
Adjustable Auto Close Func on
5