TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##281
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##282
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##283
TX
Re-transmission of the procedure signal has been attempted the specified number of times, but failed.
##284
TX
After TCF transmission, DCN has been received.
##285
TX
After EOP transmission, DCN has been received.
##286
TX
After EOM transmission, DCN has been received.
##287
TX
After MPS transmission, DCN has been received.
##288
TX
After EOP transmission, a signal other than PIN, PIP, MCF, RTP, RTN has been received.
##289
TX
After EOM transmission, a signal other than PIN, PIP, MCF, RTP, RTN has been received.
##290
TX
After MPS transmission, a signal other than PIN, PIP, MCF, RTP, RTN has been received.
##670
TX
In V.8 late start, the DIS V.8 ability from the receiving machine was detected, and CI was sent in
response; however, the procedure failed, causing T1 time-over.
##671
RX
In V.8 call reception, the procedure fails to proceed to phase 2 after CM detection, causing T1 time-over.
##672
TX
In V.34 transmission, the procedure fails to proceed from phase 2 to phase 3 or later, causing T1 time-
over
##673
RX
In V.34 reception, the procedure fails to proceed from phase 2 to phase 3 or later, causing T1 time-over
##674
TX
In V.34 transmission, the procedure fails to proceed from phase 3 or 4 to the control channel or later,
causing T1 time-over
##675
RX
In V.34 reception, the procedure fails to proceed from phase 3 or 4 to the control channel or further,
causing T1 time-over
##750
TX
After transmitting PPS-NULL in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##752
TX
After transmitting PPS-NULL in ECM transmission, DCN has been received.
##753
TX
After transmitting PPS-NULL in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##754
TX
After transmitting PPS-NULL in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##755
TX
After transmitting PPS-MPS in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##757
TX
After transmitting PPS-MPS in ECM transmission, DCN has been received.
##758
TX
After transmitting PPS-MPS in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##759
TX
After transmitting PPS-MPS in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##760
TX
After transmitting PPS-EOM in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##762
TX
After transmitting PPS-EOM in ECM transmission, DCN has been received.
##763
TX
After transmitting PPS-EOM in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed, or T5 time-over (60 sec.) has occurred.
##764
TX
After transmitting PPS-EOM in ECM transmission, re-transmission of the procedure signal has been
attempted the number of specified times but failed.
##765
TX
After transmitting PPS-EOP in ECM transmission, no significant signal has been received, and re-
transmission of the procedure signal has been attempted the number of specified times but failed.
##767
TX
After transmitting PPS-EOP in ECM transmission, DCN has been received.
##768
TX
After transmitting PPS-EOP in ECM transmission, re-transmission of the procedure signal has been