OPERATION OF FX SERIES PUMP
1. Open all valves, allowing fluid to flow through pump.
2. If an air lock occurs and no water appears to fill pump housing once the valves have been opened, release
outlet barrel union slowly until a small amount of water escapes from the pump then re-tighten.
3. Switch on power to pump, motor to start.
4. If some flow of water does not establish within on half minute, switch off and repeat procedure 3 again. If
pump does not prime within 3 attempts, check all valves and jets are in the open position.
Notes: The pump is not intended for use by young children or infirm persons without supervision. Please ensure
that young children are supervised to ensure that they do not play with the pump.
To avoid a safety hazard, the supply cord if damaged, must only be replaced by AstralPool, or its service agent or
a suitably qualified person.
MAINTENANCE
AstralPool pumps are designed to operate for extended periods with minimal attention or maintenance. Following
are the periodic maintenance requirements:
1. Keep the lint basket clean – empty it regularly. Blocked lint basket or suction pipe and no water flow can
cause overheating with consequent pipe and pump components failure and meltdown.
2. Apply suitable waterproof grease to the lint pot "O" ring to ensure positive seal.
3. Ensure electrical passage for cooling airflow to prevent fusing or shock hazards.
4. Maintain clear passage for cooling airflow to prevent overheating of motor.
5. Maintain water in good chemical balance.
6. Do not allow quantities of sand of grit to continuously pass through pump to prevent "sand blasting"
erosions (use filter sock in lint basket if sand, etc. is being picked up by vacuum.)
7. Do not over tighten strainer lid. Never use a tool or handle to tighten lid, the lid is designed to prevent this
from happening.
8. Do not add pool salt, chlorine, acid or other chemicals directly to your skimmer. This may result in damage
to your pump and could void your warranty.