Astria Fireplaces ORION32ZB6 Instrukcja instalacji i obsługi - Strona 11

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Kominek wewnętrzny Astria Fireplaces ORION32ZB6. Astria Fireplaces ORION32ZB6 20 stron. Universal vent-free firebox

Astria Fireplaces ORION32ZB6 Instrukcja instalacji i obsługi

FRAMING SPECIFICATIONS

Framing Dimensions
Opening
ORION32ZB6
ORION32ZP2
A
38-1/4 (972)
B
40-1/4 (1022)
C
19-5/8 (499)
D
10-1/4 (260)
E
59-3/4 (1518)
F
29-7/8 (759)
G *
20-1/2 (521)
H
42-1/4 (1073)
Table 1 - This Table corresponds to Figures 7, 8 and 9
* Back wall of chase/enclosure including finishing materials, if any.
WARNING:
• Do not fill spaces around
the firebox with insulation
or other materials.
• Do not notch framing or
alter the spacers on the
appliance.
This Figure corresponds
to Table 1
Figure 7
Hood Kit Installation
The firebox canopy (hood) shall not be modified or replaced with
a canopy that may be provided with the unvented decorative
room heater.
NOTE: A hood comes standard and is required. The factory-supplied
hood must be installed on the firebox for safe operation in all installa-
tions. See Figure 11.
These hood kits are design to be fitted to the face of the appliance directly
above the firebox opening. In addition to providing an aesthetically pleasing
appearance to your appliance, the hood reduces heat effects to decora-
tive mantels and finish materials located directly above the fireplace and
reduces the Mantel / Trim clearances (see Figure 4 on Page 7).
Please read this entire manual and understood thoroughly before proceed-
ing with the installation of these kits.
Step 1. Using a 5/16" nut driver or socket, remove the screen and rod
assemblies as shown in Figure 10.
Step 2. Align the hood with the holes in the side frames as shown in
Figure 11. Install three screws as shown in Figure 11. Make
sure hood is level and secure.
Step 3. Reinstall screen and rod assemblies (see Figure 10).
ORION36ZB6
ORION42ZB6
ORION36ZP2
ORION42ZP2
42-1/4 (1073)
48-1/4 (1226)
40-1/4 (1022)
40-1/4 (1022)
23-5/8 (600)
29-5/8 (753)
12-1/4 (311)
15-1/4 (387)
63-3/4 (1619)
69-3/4 (1772)
31-7/8 (810)
34-7/8 (886)
20-1/2 (521)
20-1/2 (521)
45 (1143)
49-3/8 (1254)
Header
B
A
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Corner Installation
This Figure corresponds to Table 1
H
C
Figure 8
Parallel Installation
Rough Framing Face
(Unfinished Shown)
Figure 9
Removing Screens and Rods:
Remove screws (see dotted
lines). Pull out rods from
locating holes on side of firebox
opening.
Reinstalling Screens and Rods:
Insert rods into corresponding
locating holes on sides of firebox
opening, then reinstall screws
as shown.
Figure 10
Back Wall Of Chase/Enclosure
Including Finishing Materials If Any
D
G
A
E
Rough Framing Face
(Unfinished Shown)
Back Wall Of Chase/Enclosure
Including Finishing Materials If Any
C
G
A
This Figure corresponds
to Table 1
F
11