Astria Fireplaces ODYSSEY 36 Series Informacje o produkcie - Strona 2
Przeglądaj online lub pobierz pdf Informacje o produkcie dla Kominek zewnętrzny Astria Fireplaces ODYSSEY 36 Series. Astria Fireplaces ODYSSEY 36 Series 2 stron. Outdoor vent-free gas fireplace
Cat. No.
Model
F0584
Odyssey36ZNM
F0585
Odyssey36ZPM
F0586
Odyssey36ZNM
F0587
Odyssey36ZPM
F0588
Odyssey36ZNM
F0589
Odyssey36ZPM
F0590
Odyssey36ZNM
F0591
Odyssey36ZPM
Wall board or facing
material (above
Facing material above
firebox) may be of
firebox must be of
combustible material,
noncombustible material.
including decorative
A 12" concrete board
mantel ornaments or
projecting the width of
other similar projec-
the fireplace is supplied.
tions off of the facing
material.
Framing
Material
Firebox
Wire-mesh
Screen
Steel Stud or Steel
Framing Required.
Combustible materials
not allowed adjacent to
fireplace.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Printed in U.S.A. © 2016 Innovative Hearth Products
P/N 900698-00 REV. A 11/2016
ODYSSEY™ 36/42 SERIES
OUTDOOR VENT-FREE GAS FIREPLACE
Liner Weight Cu. Ft.
Cat. No.
WS
237 lb.
23.4
F0592
WS
237 lb.
23.4
F0593
F0594
WH
237 lb.
23.4
WH
237 lb.
23.4
F0595
RS
237 lb.
23.4
F0596
F0597
RS
237 lb.
23.4
RH
237 lb.
23.4
F0598
F0599
RH
237 lb.
23.4
Mantel Shelf
Note: Any portion of the
Inch (millimeter)
mantel shelf must NOT
extend beyond this profile.
12 (305)
6-3/4 (172)
1-1/2 (38)
Noncombustible
Material May
(407)
Project Off this
Surface above
12
the Firebox Hood
(305)
Note: All vertical
measurements are
NOTE: All vertical
Supplied
Hood MUST
from top of fireplace
Firebox Hood
measurements are from
be used if a
hood opening to
Must Be Used
top of fireplace hood
combustible
bottom of mantel shelf.
at All Times
opening to bottom of
mantel is
These minimum
mantel shelf.
installed.
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Model
Liner Weight Cu. Ft.
Odyssey42ZNM
WS
312 lb.
Odyssey42ZPM
WS
312 lb.
Odyssey42ZNM
WH
312 lb.
Odyssey42ZPM
WH
312 lb.
Odyssey42ZNM
RS
312 lb.
Odyssey42ZPM
RS
312 lb.
Odyssey42ZNM
RH
312 lb.
Odyssey42ZPM
RH
312 lb.
Minimum Wall and Ceiling Clearances (see figure below)
A. Clearances from the side of the fireplace cabinet to any combustible
material and wall should follow diagram shown here.
Example: The face of a mantel, bookshelf, etc. is made of combustible
material and protrudes 3-1/2" from the wall. This combustible mate-
rial must be 4" from the side of the fireplace cabinet.
B. Clearances from the top of the firebox opening to the ceiling should
not be less than 42".
20
(508)
C. When the firebox is installed directly on carpeting, vinyl tile or other
combustible material, other than wood flooring, the firebox should be
16
installed on a metal or wood panel extending the full width and depth
of the enclosure.
D. Clearances from the bottom of firebox to the floor is 0".
PFS
34.3
34.3
C
34.3
34.3
Report No. F09-026
34.3
These appliances comply with National Safety
34.3
Standards and are listed by PFS Corporation
to ANSI Z21.11.2 as unvented Gas-fired
34.3
room heaters.
34.3
Inch (millimeter)
Example
1/2
1
2
4
6
8
10
12
(102)
(13)
(26)
(51)
(153)
(204)
(254)
(305)
12'' minimum noncombustible
wall board or facing material
above fireplace.
12'' minimum noncombustible
wall board or facing materials on
sides.
Specifications and clearances are subject to change without
notice. Refer to Installation Manual before installation of
these appliances for updated dimensions and instructions.
®
US
12-1/4 (312)
10-1/2 (267)
8-3/4 (223)
7 (178)
5-1/4 (134)
3-1/2 (89)
1-3/4 (45)
7/8 (23)
1/2 (13)
14
16
(356)
(407)
Page 2 of 2