Dorlen SS-2100 Water Alert Instrukcje

Przeglądaj online lub pobierz pdf Instrukcje dla Czujniki bezpieczeństwa Dorlen SS-2100 Water Alert. Dorlen SS-2100 Water Alert 2 stron.

DORLEN
DORLEN
LIQUID LEAK DETECTION SYSTEMS SINCE 1975
R
Mfgr. of:
PRINCIPLE OF OPERATION
Refer to Figure 1. The SS-2100 is activated by liquid bridging the adjustable sensors (A & A). The unit can
detect water film from zero height, (sensors turned out to make contact with the floor), to 1/8" height, (sensors
turned all the way in). The units are factory adjusted to activate with 1/32" water film height which is satisfactory
for most applications. The pads B1, B2, B3 provide a gap between the case and the surface to admit water
under the unit for detection. CAUTION: If the pads are removed, the unit may form a seal with the surface and
prohibit the sensors from detecting water. If desired, the self-adhesive pad feature may be used by peeling off
the thin protective layer from each pad. The unit will remain in place when located on the mounting surface.
Replacement pads are available from Dorlen at no charge.
If you have installation questions,
call toll free 1-800-533-6392
1
2
3
4
5
6
Alert Actvated
System Powered
Monitor
Although the two sensors (A & A) may be adjusted to make contact with the surface, it is recommended
that a small gap be set between the sensors and the surface so undesired activation, caused by damp-
ness or dirt film, does not occur.
Products Inc.
CEILING
Instructions for
Model
SS-2100
3
-CONDUCTOR
CABLE
2500'
Max.
SERIES 2100
To 110 VAC
Not For Explosive Environments!
SYSTEMS INSTALLIED IN OVER 25,000 SITES!
GUARD
R
Oil Alert
Oil Alert
Water Alert
A
B1
FLOOR
WHEN WATER FILM FORMS
A BRIDGE BETWEEN SEN-
SORS (A&A), WATER ALERT
IS ACTIVATED.
Figure 1
NOTE
CAUTION
6615 W. Layton Ave. Milwaukee, WI 53220
Phone: (414) 282-4840
www.wateralert.com
R
www.oil-alert.com
®
Model SS-2100 Bottom View
SS-2100
A
B2
A
A
FLOOR
Page 1 of 2
FAX: (414) 282-5670
1-19 M-9860