Canon LV-5220 - Multimedia Projector SVGA Specyfikacja funkcjonalna - Strona 27

Przeglądaj online lub pobierz pdf Specyfikacja funkcjonalna dla Projektor Canon LV-5220 - Multimedia Projector SVGA. Canon LV-5220 - Multimedia Projector SVGA 42 stron. Multimedia projectors
Również dla Canon LV-5220 - Multimedia Projector SVGA: Specyfikacja funkcjonalna (20 strony), Specyfikacje (6 strony)

Canon LV-5220 - Multimedia Projector SVGA Specyfikacja funkcjonalna
Expand Serial Command Functional Specification

8.11.14. CF_STANDBYMODE Command

Command
"CF_STANDBYMODE_%1" [CR]
"ECO" ------------ Standby power requirement is smaller
%1
"NORMAL" ----- Normal Standby power requirement
Details
Set Standby mode. (Only valid when it is in the usual Power On status)
Acceptable
Response
Unacceptable

8.11.15. CF_POINTER Command

Command
"CF_POINTER_%1_%2" [CR]
"SPOTLIGHT" --------- Select Spotlight
"ARROW" --------------- Select Arrow
%1
"FINGER" -------------- Select Finger
"LASER" ----------------- Select Laser mark
"MAX" ---------- Maximum Spotlight
%2
"MID" ---------- Medium Spotlight
"MIN" ---------- Minimum Spotlight
Select Pointer image. (Only valid when it is in the usual Power On status)
Note1) %2 is available when "SPOTLIGHT" is specified only.
Details
Note2) When "SPOTLIGHT", %2 cannot be omitted.
Acceptable
Response
Unacceptable

8.11.16. CF_FDEFAULT Command

Command
"CF_FDEFAULT_%1" [CR]
%1
"RST"
Details
Set Factory Default. (Only valid when it is in the usual Power On status)
Acceptable
Response
Unacceptable

8.11.17. CF_AUTOSETUP Command

Command
"CF_AUTOSETUP_%1_%2" [CR]
"KEYSTONE"
%
"PCADJ"
"START"
Select Auto Setup function. (Only valid when it is in the usual Power On status)
Note1) When started Auto Setup, can not doing CF Command during end of Auto
Details
Note2) Can not "OFF" the both KEYSTONE and PCADJ.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
When "ARROW" / "FINGER" / "LASER", specify "CF_POINTER_%1" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
%1
"AUTO" ----------- Auto setting for Auto Keystone
" M A N U A L " - - - - - Manual setting for Auto Keystone
"OFF" ------------- Off for Auto Keystone
"ON" --------------- On for Auto PC Adj.
"OFF" ------------- Off for Auto PC Adj.
None
Setup. In this bout, return error code "302" if send out command.
When KEYSTONE or PCADJ is "OFF", return error code "101" if set
Keystone or PCADJ.
"000" [CR]
"Error Code" [CR]
Page 26 of 41
%2