Dormakaba 7400 SISJH Instrukcja instalacji - Strona 5
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla System otwierania drzwi Dormakaba 7400 SISJH. Dormakaba 7400 SISJH 10 stron. Applied door closer, spring stop arm for regular
![Dormakaba 7400 SISJH Instrukcja instalacji](/uploads/products/server2/1196928/1196928.png)
dormakaba 7400 SIS, SISJ, SISH, SISJH Installation Instructions
2.2 Securing main arm to door/frame
Fig.3
Pinion
screw
Pinion
Damper
Adjusting
tube
2.2.1
Secure adjusting tube to damper.
•
Use one 7/8" x 1/2" torx head shoulder bolt provided.
2.2.2
Secure damper assembly to frame.
•
Use two 5/16" x 2" flat head screws
[#20 x 2" flat head wood screws] provided.
2.2.3
Secure main arm to operator pinion.
2.2.4
Use a torque wrench (25 ft-lbs) and provided pinion
screw [M8 x 30 socket head cap screw].
2.3 Securing main arm to closer
Fig.4
Door
Damper
assembly
Main arm
Hinge
2.3.1
Slide end of connecting arm into end of damper
assembly.
7400 Surface Applied Closers
Non-hold open
Main/
connecting
arm assembly
Adjusting
tube
Damper/
Damper
assembly
Right hand
door shown
7/8"x1/2"
torx head
shoulder bolt
Right hand
door shown
Connecting
arm
08279501
Hold open
plate
Right Hand (RH)
Configuration
Plate pointing to the
RIGHT
Hold open
Main/
connecting
arm assembly
Damper
NOTE: To disassemble hold open plate:
2.2.5
Remove both screws from bottom of plate using a 3/16"
hex key.
2.2.6
Keeping all washers in place, flip plate over to orient as
per image above.
2.2.7
Re-secure plate with both screws.
2.3.2
Secure connecting arm and damper assembly.
2.3.3
Use provided fastener [5/16-18 x 3/8 hex bolt].
Regular mount
Left Hand (LH)
Configuration
Plate pointing to the
LEFT
Pinion
screw
Pinion
Right hand
door shown
Right hand
door shown
5/16-18 x 3/8"
hex bolt
01-2021
5