Akytec MU110-6U Podręcznik użytkownika - Strona 7
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Systemy wejścia/wyjścia Akytec MU110-6U. Akytec MU110-6U 18 stron. Analog output module 6 channel
Installation
4.1.2
MU110-6U has 6 analog outputs 0-10 V which can be controlled via RS485 network.
Table 4.1 Terminal assignments
No
1
2
3
4
5
6
7
8
9
10
11
12
►
The voltage of an external auxiliary voltage source may not exceed 36 V.
NOTICE
The output is designed for minimal load resistance of 2 kohm.
akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de
Outputs
Fig. 4.1 Electrical connections
Indication
Description
0V
Power supply
24V
Power supply
not connected
NC
AO1A
Output 1 / 0-10 V
AO1B
Output 1-
AO1C
Output 1+
AO2A
Output 2 / 0-10 V
AO2B
Output 2-
AO2C
Output 2+
AO3A
Output 3 / 0-10 V
AO3B
Output 3-
AO3C
Output 3+
Fig. 4.2 Output wiring
No
Indication
13
D-
14
D+
15
not connected
16
AO4A
Output 4 / 0-10 V
17
AO4B
18
AO4C
19
AO5A
Output 5 / 0-10 V
20
AO5B
21
AO5C
22
AO6A
Output 6 / 0-10 V
23
AO6B
24
AO6C
Description
RS485 D-
RS485 D+
NC
Output 4-
Output 4+
Output 5-
Output 5+
Output 6-
Output 6+
6