Dot-Spot brilliance 24 V monochrome Instrukcja obsługi - Strona 17
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Oświetlenie krajobrazu Dot-Spot brilliance 24 V monochrome. Dot-Spot brilliance 24 V monochrome 20 stron. Recessed luminaire
Possible failures
Failure
brilliance does
not light up
Spot flashes or is
dimly lit
Humidity inside the
spot housing
Technical data
Model
Power
Tension
Light intensity
Housing
Glass plate
Illuminant
Dispersion angle
Pivoting range
Axial range
Loading capacity
Installation Ø
Installation depth
Protection class
Possible failures / technical data
Cause
Check cabling
Correct fault
Check power supply
Power supply overloaded
Cable damaged
Pressure ring not properly
screwed tight
brilliance 24 V monochrome
10 W
24 V
570 lm
Completely in V4A 1.4404, AISI 316L
8 mm safety glass
LED
10, 20, 25 and 35 degrees
+/- 25 degrees
360 degrees
for loads of up to 5 tons
75 mm
min. 80 mm
IP 68
Corrective measure
Cabling, check power supply
polarity
Use power supply with proper
power
Replace cable
Remove ball spot glass,
slightly grease the O-ring with
Vaseline, reassemble spot
tightly
brilliance RGB
10 W
12 V
400 lm
8 mm safety glass
LED
10, 20, 25 and 35 degrees
+/- 25 degrees
360 degrees
for loads of up to 5 tons
75 mm
min. 80 mm
IP 68
17