Assembly
Installation using the ground spike
Drive the ground spike into the ground using a suitable tool. When using a metal hammer, please
put a piece of wood or the like between the hammer and the ground spike in order to protect the
latter. Then, screw the mounting bracket with the luminary onto the ground spike using the screw
and the snap ring provided with the ground spike. The snap ring is placed between screw head and
mounting bracket. Orientate the mounting bracket before screwing it down.
Installation using the mounting extension
The mounting extensions are designed for the use with the ground spike.
Screw the mounting extension onto the ground spike using the threaded pin. Screw tight the mount-
ing extension: in order to do so, use a pair of pliers and put a cloth or the like around the mounting
extension.
Then, screw the mounting bracket with the luminary onto the mounting extension using the screw
and the snap ring provided with the ground spike. The snap ring is placed between screw head and
mounting bracket. Orientate the mounting bracket before screwing it down.
Installation of other accessories
During the installation of other accessories, refer to the respective installation instructions attached.
Connection
Attention:
The design of the complete system and of the required power supplies must be carried
according to the protective low voltage SELV prescriptions!
The clarios eco models with white light color and open connection cable can be dimmed by means
of a separate PWM signal (pulse-width modulation). The colored models of the clarios eco 10 W
can also be dimmed if they contain plug connectors in the variant. The PWM input (open cable) has
the following characteristics:
PWM line connected to ground (-)
PWM line open
PWM line connected to operating voltage (+)
PWM frequency = 0 to 1,000 Hz
The switching point of the luminary between on and off for the PWM level is not defined: Ideally it
should be worked with a switching impulse between ground and open contact or optionally with an
impulse between ground and operating voltage. A PWM signal differing from the operating voltage
is not allowed.
22
Light colors
White light colors
blue, green, amber, red
LED off
LED on
LED on
LED off
LED on
LED off
Assembly
Free cabling
The connect is made according to the assignment tables. The connection must be carried out ac-
cording to the required IP classification.
clarios eco
Wire color
red
blue
black
Attention:
In case the luminary of the colored version is used without the dimming function, the
PWM line (wire for the PWM signal) must be connected to ground (-). Otherwise the LED remains off.
Connection diagram of the clarios white / monochromatic without dimmer
See respective drawing in the middle of this manual (p. 14).
M12 plug and cabling system
The connection of the clarios eco versions with M12 connector is quite simple. Plug the connector
of the luminary in a free socket of the M12 cabling system. The M12 cabling system is coded in a
way to avoid wrong wiring or failures.
Note: clarios eco models with white light color are not dimmable when using the plug system.
Please plan the components required for the electrical installation (power supplies, distributors,
extensions and plugs for unassigned M12 sockets) according to the sales documentation of the
M12 cabling system before placing an order.
Assignment of the M12 connector system
Pin number
Wire color
M12 plug
(if plug is pinched off)
1
brown
2
white
3
blue
4
black
5
green/yellow (gray)
Assignment
+ 24 Volts
S-PWM
ground (-)
5-pin plug clarios eco
white / monochromatic
24 V +
24 V +
S-PWM (only colored version)
Masse
ground