Setting 2 Group
(PRG Button Push for 10 Sec.)
No
Menu
4 0061
Lock Function
4 0062
Sensor Type
4 0063
Max. Sensor Input Range
4 0064
Min. Sensor Input Range
4 0065
Unit of temperature
4 0066
Decimal Point Display(※2)
4 0067
Sensor Correction(※3)
4 0068
Sensor Input Filter
4 0069
Sensor Value Display Cycle
Operation Cycle Output at Error
4 0070
Occurrence #1(※4)
Operation Ratio Output at Error
4 0071
Occurrence #1(※4)
Analogue Trans.
4 0072
Output(4~20mA) Mode
(-A1 model)
4 0073
Setup Value Unication Mode (※5)
Output #2, Select Extended
4 0074
Function.
(Display TY2 as OFF )
Output #2, Timer OFF Time
4 0075
(Defrost Cycle)
Output #2, Timer ON Time
4 0076
(Defrost Time)
4 0077
Alarm Range High Limit (※7)
4 0078
Alarm Range Low Limit (※7)
4 0079
Alarm Sensing Hysteresis
4 0080
Communication Address (※8)
STD
(※1)
: Sensor Value Display Value : Display set value of output 1,2 as present value by input ON/OFF.
(※2) Decimal Point Display : Decimal point display : It sets the current value display unit as 0.1/1. i.e. In case of setting as '1', it displays the current value with cutting the decimal place.
(※3) Correct Temp. Sensor : Correct deviations of temperature sensor. e.g) if displayed temperature is 19°C and actual temperature is 18°C, it is corrected by inputting -1.0°C
(※4) Control Output Operation at Error Occurrence : When error occurs, control output repeatedly operates OFF/ON until error is reset.
e.g) In case of setting of operation cycle : 60minutes, ON ratio 20%, it repeatedly operates a cycle of OFF (48 minutes) / ON (12 minutes).
(※5) Setup Value Unication Mode : In case of setting this function as ON, setup value is unied and controlled as 1 case.
(※6) Manual Reset alarm : In case of selecting manual reset alarm, it is reset by re-inputting power or pushing PRG button rapidly 2 times.
(※7) In case of occurrence of high or low limit alarm, it doesn't aect control output #1 at all.
(※8) Communication Address : Master mode address is to -1 from -64.
Communication
Transmission line connection
Multiple line
Communications method
RS485 (2-wire, half-duplex)
BPS
BPS default 4800 BPS
Parity, Data, Stop bit
None, 8 Data, 1 Stop
Protocol Type
Modbus RTU Mode
Function Code
Read HOLD REGISTERS (0x03) / Preset Single Register (0x06)
Poll interval
100msec
Communication Table
No
4 0101
Product status codes
Bit 0
Output 1 ON / OFF status
Bit 1
Output 2 ON / OFF status
Bit 8
Defrost output ON / OFF status
Bit 12
Min. range alarm
Bit 13
Max. range alarm
Bit 14
Sensor (disconnection, short-circuit) Alarm
Bit 15
EEPROM alarm
4 0102
Current temperature value (PV)
4 0103
FND display current temp. value (PV)
4 0104
Output 1 ( ST1 ) settings ( * read only)
4 0105
Output 2 ( ST2 ) settings ( * read only)
4 0107
Command of compulsory defrost with manual
4 0108
Command of compulsory defrost termination
Code
OFF (0) : Lock cancel
LC 1 (1) : Setting 2 group lock
LOC
LC2 (2) : Setting 1,2 group lock
LC3 (3) : Setting 1, 2 group, temp. setup lock
TH 1 (0) : DPR-TH01 (-50~105°C)
TH2 (1) : DPR-TH02 (-50~150°C)
420 (2) : 4-20mA signal input
IN
ST 1 (3) : OUT1 set temperature ( ST1 ) display
ST2 (4) : OUT1 set temperature ( ST2 ) display
STD (5) : ST 1 or ST2 (※1)
SH
SL
UNT
0. 1 (0) : Decimal point display
DP
COR
SFT
SDT
CL1
DU1
PV (0) : Current Temp.
C (2) : Cooling proportional control
AOM
ST 1 (3) : Set value Temp.#1 ST2 (4) : Set value Temp.#2
OFF (0) : Output #1, #2 separation mode
STO
0N (1) : Unication mode
OFF (0) : Control output operate as the function set at TY2
AL1 (1): Output ON at sensor alarm +
high limit alarm
AL2 (2): Output ON at sensor alarm +
N2
low limit alarm
AL3 (3): Output ON at sensor alarm +
high/low limit alarm
T1M (7) : Timer output
DFH (8) : Timer output
DFG (9) : Timer output
OF2
ON2
ALH
ALL
AHY
ADR
Menu
Unit
°C
°C
°C
°C
Unit
Step
(In case of connecting with press.&humidity sensor)
°C
1
°C
1
oC (0) : Celsius
1 (1) : Do not display decimals
°C
0.1
Sec
0.1
Sec
0.1
Min
1
%
1
H (1) : Heating proportional control
Automatic reset alarm
Manual reset alarm(※6)
AL4 (4): Output ON & manual reset at
sensor alarm + high limit alarm
AL5 (5): Output ON & manual reset at
sensor alarm + low limit alarm
AL6 (6): Output ON & manual reset at
sensor alarm + high/low limit alarm
(Regular cycle timer output)
(Regular cycle timer output : heater defrost)
(Regular cycle timer output : hot gas defrost)
Min
1
Min
1
-
0.1
-
0.1
K
0.1
-
1
Change of BPS
Default value of this model is 4800bps and it should be changed separately.
FX3D
OUT1
OUT2
Type
Size (Word)
Digital
INT 16
Digital
Bit
Digital
Bit
Digital
Bit
Digital
Bit
Digital
Bit
Digital
Bit
Digital
Bit
Analog
INT 16
Analog
INT 16
Analog
INT 16
Analog
INT 16
Analog
INT 16
Analog
INT 16
- 4 -
Min
Max
SL
999
-1 99
SH
oF (1) : Fahrenheit
-1 9.9
1 9.9
0.1
5.0
0
5.0
0
999
0
1 00
0
999
0
999
ALL
SH
SL
ALH
0
99.9
-64
64
1. Entry into parameter relating to BPS
PRG
SEL
Press
+
+ ▲ + ▼ buttons simultaneously
for 5 seconds as shown in the figure
BDR
2.
BDR Communication Speed (Press the SEL button eight times)
Adjust BPS using ▲ / ▼ buttons from the
48
96
(
: 4800bps,
: 9600bps,
3. Store set value (Press the SEL button for three seconds)
FX
Refer to bit status below
0 : OFF
1 : ON
0 : OFF
1 : ON
0 : OFF
1 : ON
0 : Normal
1 : Alarm
0 : Normal
1 : Alarm
0 : Normal
1 : Alarm
0 : Normal
1 : Alarm
-50 ~ 105
-50 ~ 105
-50 ~ 105
-50 ~ 105
1 : START (Auto-reset)
1 : STOP (Auto-reset)
Default
Custom Setup
OFF (0)
TH 1 (0)
1 05
-50
oC (0)
0. 1 (0)
0.0
2.0
0.5
OFF (0)
50
PV (0)
OFF (0)
OFF (0)
360
30
30.0
-1 0
1 .0
1
BDR
parameter
1 92
384
: 19200bps,
: 38400bps)
MMI
Scale
-500 ~ 1050
1/10
-500 ~ 1050
1/10
-500 ~ 1050
1/10
-500 ~ 1050
1/10