Baumer 10161446 Instrukcja obsługi

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Akcesoria Baumer 10161446. Baumer 10161446 2 stron. Ultrasonic proximity sensor

Ultraschall-Sensoren
Ultrasonic sensors
Détecteurs à ultrasons
UNDK 10N8914/S35A
Näherungsschalter
Proximity sensor
Détecteur de proximité
IND. CONT. EQ
10161446
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Canada
Italy
Baumer Inc.
Baumer Italia S.r.l.
CA-Burlington, ON L7M 4B9
IT-20090 Assago, MI
Phone +1 (1)905 335-8444
Phone +39 (0)2 45 70 60 65
China
Singapore
Baumer (China) Co., Ltd.
Baumer (Singapore) Pte. Ltd.
CN-201612 Shanghai
SG-339412 Singapore
Phone +86 (0)21 6768 7095
Phone +65 6396 4131
Denmark
Sweden
Baumer A/S
Baumer A/S
DK-8210 Aarhus V
SE-56133 Huskvarna
Phone: +45 (0)8931 7611
Phone +46 (0)36 13 94 30
France
Switzerland
Baumer SAS
Baumer Electric AG
FR-74250 Fillinges
CH-8501 Frauenfeld
Phone +33 (0)450 392 466
Phone +41 (0)52 728 1313
Germany
United Kingdom
Baumer GmbH
Baumer Ltd.
DE-61169 Friedberg
GB-Watchfield, Swindon, SN6 8TZ
Phone +49 (0)6031 60 07 0
Phone +44 (0)1793 783 839
India
USA
Baumer India Private Limited
Baumer Ltd.
IN-411058 Pune
US-Southington, CT 06489
Phone +91 20 66292400
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
1/2
Abmessungen
Dimensions
Dimensions
12
M8 x 1
10,4
1DD2
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Bedienungsanleitung
Teach-in Verriegelung 5 min. nach jedem Power-up,
bzw. nach dem Ende des letzten Teach-in Vorgangs.
Einstellung Schaltpunkt Sde
1. Den Sensor in den Einstellmodus bringen:
Teach-in-Taste ca. 2s drücken oder externen Teach-
in-Anschluss mit +Vs verbinden bis die LED grün
blinkt. Taste loslassen bzw. die Verbindung öffnen.
2. Die LED blinkt grün. Das Objekt an die gewünschte
Bereichsgrenze bringen und die Teach-in-Taste kurz
drücken oder den externen Teach-in-Anschluss kurz
mit +Vs verbinden.
3. Bestätigung des erfolgreichen Teach-Vorgangs durch
Leuchten beider LEDs für 2s.
Einstellung der Ausgangafunktion (NO/NC)
1. Den Sensor in den Einstellmodus bringen:
Teach-in-Taste ca. 4s drücken oder externen Teach-
in-Anschluss mit +Vs verbindenbis die LED rot
blinkt. Taste loslassen bzw. die Verbindung öffnen.
2. Die LED zeigt nun die Ausgangsfunktion an. Grün be-
deutet Schliesser, rot Öffner. Durch kurzes Drücken
der Taste oder kurzes Verbinden des externen Teach-
in-Anschlusses mit +Vs kann die Ausgangsfunktion um-
geschaltet werden.
3. Die gewählte Ausgangsfunktion wird abgespeichert
indem die Teach-in-Taste ca. 2s gedrückt oder der
externe Teach-in Anschluss ca. 2s mit +Vs verbunden
wird. Bestätigung des erfolgreichen Teach-Vorgangs
durch Leuchten beider LEDs für 2s.
14
Teach-in
LED
3
3,2
2,9
7
Operating instructions
Teach-in locking 5 min. after every power-up,
respectively after the end of the last Teach-in process.
Adjustment switching point Sde
1. Adjustment mode:
Press the Teach-in button or connect the white
Teach-in wire to +Vs for approx. 2 secs until the LED
flashes green. Release button or disconnect
Teach-in wire.
2. LED flashes green. Place the target at the required
scanning range and press the Teach-in button or
connect the external white Teach-in wire shortly
to +Vs.
3. Successful completion of Teach-in procedure is
confirmed by both LEDs being „on" for approx. 2 secs.
Programming of output function (NO/NC)
1. Adjustment mode:
Press the Teach-in button ot connect the external
Teach-in wire to +Vs for approx. 4 secs until the LED
flashes red. Release button or disconnect
Teach-in wire.
2. The LED shows the output function of the sensor.
Green indicates NO, red indicates NC. Output
function is changed by either holding down the
Teach-in button or by connecting the external
Teach-in wire to +Vs for a short time.
3. The chosen output function is saved by holding
down the Teach-in button or by connecting the
external Teach-in wire to +Vs for approx. 2 secs.
Successful completion ot the Teach-in procedure is
confirmed by both LEDs being „on" for approx. 2 secs.
Elektrischer Anschluss
Connection diagrams
Schéma de raccordement
BN (1)
+V
S
Z
BK (4)
NPN
output
BU (3)
0 V
WH (2)
control/Teach-in
oder
NPN Öffner (NC)
NPN Schliesser (NO)
or
NPN break function (NC)
NPN make function (NO)
ou
NPN à fermeture (NO)
NPN à ouverture (NC)
4 / Output
2 / cont/Teach-In
Anschlussbelegung
Pin assignment
Raccordement
1 / +V
3 / 0 V
S
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten
• Disconnect power before connecting the sensor
• Mettre l'installation hors tension avant le raccordement du détecteur
Notice d'utilisation
Verrouillage du Teach-in 5 min après chaque mise sous
tension resp. après la fin du dernier processus Teach-in.
Ajustage du point de commutation Sde
1. Ajustage:
Presser le bouton Teach-in ou connecter le Teach-in
externe avec +Vs pendant environ 2 secondes
jusqu'à ce que la LED vert clingote.
Relâcher le bouton ou déconnecter le Teach-in externe.
2. LED clignote en vert. Placer l'objet à détecter à la
distance désirée et presser le bouton Teach-in ou
connecter brièvement le Teach-in externe (WH)
avec +Vs.
3. La validation de la procédure Teach-in est confirmée
par l'état de fonctionnement des deux LEDs
pendant 2 secs.
Réglage de la fonction de sortie (NO/NC)
1. Ajustage:
Presser le bouton Teach-in ou connecter le fil du
Teach-in externe sur +Vs pendant 4s environ jusqu'à
ce que la LED rouge clignote. Relâcher ensuite le
bouton ou déconnecter le fil.
2. La LED indique la fonction de sortie du détécteur.
Vert pour NO, rouge pour NC. Vous pouves ainsi
changer la fonction de sortie en appuyant rapidement
sur le bouton Teach-in ou connectant rapidement le
fil du Teach-in externe sur +Vs.
3. Valider la fonction de sortie choisie en pressant le
bouton Teach-in ou en connectanc le fil du Teach-in
externe sur +Vs pendant 2s environ. Les LED rouge
et verte s'allument pendant 2s pour confirmer que
le réglage a bien été pris en compte.
BN = Braun/brown/brun
BK = Schwarz/black/noir
BU = Blau/blue/bleu
WH = Weiss/white/blanc