Colzer CFT4.0D Podręcznik użytkownika - Strona 9

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Osuszacz powietrza Colzer CFT4.0D. Colzer CFT4.0D 17 stron.

Colzer CFT4.0D Podręcznik użytkownika
inlet air which is similar to the room temperature. However, if the timer function is being
set or has been activated, the small font digital number will turn to display the timer
setting value or time remaining.
Running Icon:Running icon flickers typically because the compressor has not kicked in. It
usually happens 1) when the dehumidifier is under the 3-minute compressor delay status; 2)
when the dehumidifier is programmed to delay-start (AUTO ON TIMER).
Wet Controller Icon: Wet Controller Icon flickers when the room humidity level (inlet
humidity reading) is 3% lower than the set humidity.
1) When you see the "wet controller" icon illuminating while setting up, it typically means
the set humidity level is not 3% lower than the inlet humidity reading. Please make sure
the set humidity value is at least 3% (10% recommended) lower than the inlet humidity
reading.
2) In Humidistat Mode, if you see "wet controller" icon illuminating after running the
dehumidifier for a while, it means the dehumidifier has got the room humidity down to
the set point and the dehumidifier enters into standby mode. When the room humidity
level raises up to 3% higher than the set humidity, the dehumidifier will automatically
restart to dehumidify. That is to say, the dehumidifier will automatically stop or restart to
maintain the room humidity level within a range of ±3% of the set point.
For example, if the set humidity is 50%, when the inlet humidity level the dehumidifier detects is
47%, 3% lower than the set humidity, the dehumidifier will automatically stop and enter into "wet
controller" mode. When the inlet humidity level the dehumidifier detects raises to 53%, 3% higher
than the set humidity, it will automatically restart.
Defrosting Icon: The dehumidifier begins to defrost when the frost has accumulated on the
interior of the dehumidifier. When the dehumidifier is defrosting, the fan is running, but
the compressor is not, the defrost icon is flashing. The dehumidifying function will cease
until the frost has melted. When defrosting is complete, the defrosting Icon will disappear
and the dehumidifier begins to dehumidify again automatically.
Note: The frequent defrost process indicates that the room temperature is too cold.
Therefore, if the room temperature is lower than 60°F, please consider adding heat to
promote proper drying.
Fan Icon: The fan icon illuminates when the fan is running.
Water Droplets Icon: The water droplets icon illuminates when the compressor kicks
in, which means the dehumidifier is dehumidifying.
due to the 3-minutes delay system, this icon flickers.
When the compressor delays to start
6