Baumer 11188367 Podręcznik - Strona 28
Przeglądaj online lub pobierz pdf Podręcznik dla Akcesoria Baumer 11188367. Baumer 11188367 36 stron. Off-highway multi-object radar sensor
Również dla Baumer 11188367: Instrukcja obsługi (29 strony)
Manual R600V.DAH5 Multi-object (EN)
Address
Parameter
0x07E394
Time to wait after sending a re-
quest for address claimed mes-
sage before own address claim is
sent
0x07E39D
Compare mask for "bitwise AND"
of ISO name used for Master ECU
Detection
0x07E39E
Compare value for ISO name used
for Master ECU Detection (after
applying bitwise mask defined in
0x07E39D)
0x07E395
Delay between detection of master
address claim and starting RUN
mode
0x07E396
Delay between detection of master
address claim and first PDU1
transmission
0x07E398
Lowest device address to claim in
address resolution sequence
0x07E399
Highest device address to claim in
address resolution sequence
0x07E39A
CAN Bus speed.
0 = 250k
1 = 500k
2 = reserved (do not use)
0x07EF40
Reset device to default values
Write data in this sequence to reset all non-volatile SPNs to default values:
0x00, 0xAA, 0x55, 0x12, 0x34
(4) Detection range can be adjusted to avoid issues with double echo detections.
(5) SPN value is reset to default after a power cycle (volatile)
Page 28 of 36
range
offset
scaling
0..5000
0
1ms
0..0xffffffffffffffff
0
0..0xffffffffffffffff
0
0..5000
0
1ms
0..5000
0
1ms
128..209
0
128..209
0
0..1
0
R600V.DAH5_multiobject_manual_1.1 (EN).docm
Last Update: 01 Jan 2021
Default value
1250
1
0
1
0
250
200
1
128
1
209
1
0