CLEANING & MAINTENANCE
WARNING: Before cleaning, performing maintenance or repairs make sure
the machine is turned off and the machine is unplugged.
***This appliance is not waterproof. Never spray or pour water or
any other cleaning solution onto this appliance.***
CLEANING ALUMINUM UNCOATED HEAT PLATEN(S).
1. Unplug the machine and allow it to cool.
2. Open the heat platen for easier access.
3. Dampen a nonmetallic scrubbing sponge with a mild soap or deter-
gent to remove any excess material from the heat platen(s).
4. Wipe clean with a dry cloth.
CLEANING PTFE COATED PLATEN(S) (OPTIONAL FEATURE).
1. Unplug the machine and allow it to cool.
2. Open the heat platen for easier access.
3. Clean the PTFE coated platen with a mild soap and warm water
applied with a soft cloth or sponge. Do not use steel wool, scrub
sponges, kitchen or oven cleaners or any other kind of abrasive ma-
terial. This will damage the coating.
4. Wipe clean with a dry cloth.
CLEANING OUTSIDE SURFACES OF THE MACHINE
Use a mild soap and warm water applied with a soft cloth or sponge.
Do not use steel wool, scrub sponges, kitchen or oven cleaners or other
abrasives that will damage the painted surface.
LUBRICATION
Your press requires lubrication every
15,000 cycles or every 6 months. Lu-
bricate weekly in a heavy use produc-
tion environment. Use NSF/NLG12
rated food grade grease (such as
Bel-Ray No-Tox #2 or equivalent). A
general purpose food grade machine
oil spray is also acceptable such as
CRC03055 lubricant (available from
retailers such as Amazon). Lubricate
all moving or hinged points.
CIRCUIT BREAKER RESETTING
Should the circuit breaker trip, simply allow the machine to cool for 2
minutes and then reset the circuit breaker by pressing the button back in
to allow the machine to come back on. If the circuit breaker continues to
trip, have an electrician diagnose the cause of the fault.
15