Baumer IO-Link RR30 Instrukcja obsługi - Strona 21

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Akcesoria Baumer IO-Link RR30. Baumer IO-Link RR30 40 stron. Radar sensor

Baumer IO-Link RR30 Instrukcja obsługi
TI Result. Teach Flag SP1
TI Result. Teach Flag SP2
Analogue Output
Teach.Status

4.5 Static

By using teach commands, set point 1 and set point 2 (SP1 and SP2) can be set by placing the object at the
desired position and triggering the command. Which command is used in which order varies depending on
the active switching mode (Single-Point or Window) of the selected-teach channel and is explained below.
Parameter name
Standard Command
Standard Command
System Command (Teach
Apply)
System Command (Teach
Cancel)

4.6 Signal Processing

Process Value Exponential

4.6.1
With the help of this function slight fluctuations and outliers of the values are compensated. It must be
ensured that the switching signals are displayed with the length of the mean delay.
Parameter name
Process Value Exponential
Filter.Output Filter Time
en_BA_RR30_IO-Link_V0.23.docx
13.01.2021/
Shows the teach status of the
respective switch point
Shows the teach status of the
respective switch point
Status of the Analogue teach
output
Short Description
Teach SP1 TP1
Teach SP1 TP2
Short Description
Time over which the signal is
exponentially averaged and is
displayed as the value
(distance/velocity or amplitude).
This time is a multiple of the
smallest measurement time.
21/40
- 3 = SP1&2 Success
- 4 = Waiting for
Command
- 6 = Busy
- 7 = Error
ro
Not Taught / Taught
ro
Not Taught / Taught
ro
x (Idle / Successful / Not
Successful)
Rights
Unit / Allowed values
wo
wo
wo
wo
Rights
Unit / Allowed values
Limits: 0 to 1000.000 ms
rw
Default: 200 ms
Frauenfeld, Switzerland