4.4 Signal Processing
Measurement Mode (Only O200.G, S)
4.4.1
With this parameter pre-defined modes can be selected to achieve optimal results without much trial and
error.
Parameter name
Measurement Mode
High Speed:
Ideal for fast moving objects. Sensors is adjusted for fastest response time. Detection ability identical to
Standard-Mode but with reduced ambient light immunity
Standard:
Standard setting with outstanding performance with the highest ambient light immunity.
High Power:
Twice the excess gain compared to Standard mode but with slower response time.
Reduced hysteresis due to better signal/noise ratio.
4.5 Input/Output Settings
Switching Output
4.5.1
Parameter name
DI/DO Settings.OUT1 Circuit
DI/DO Settings.OUT1 Mode
en_BA_O200_IO-Link_V1.docx
15.08.2018/
Short Description
Choose measurement mode for
different applications
Short Description
Selection of circuit type
Selection of output source
(Default: SSC1)
20/34
Rights
Unit / Allowed values
rw
-
High Speed
-
Standard
-
High Power
Rights
Unit / Allowed values
rw
-
PushPull (default)
rw
-
None (SIO
deactivated)
-
SSC1 (default)
-
SSC4