Dynamic in Window Mode (Only O200.G)
5.3.2
If the selected SSC is configured to Window mode (Section 4.3.2.1) during the dynamic teach-in the
minimum and maximum values are evaluated. Setpoint SP1 is set to Min, SP2 is set to Max.
6
Diagnosis
In addition to solving the primary application, the simple evaluation of secondary data, such as temperature,
supply voltage or operating time, allows for predictive maintenance and thus optimum machine availability.
6.1 Device Status
Parameter name
Device Status
Detailed Device Status
6.2 Device Temperature
An integrated temperature sensor allows to track the internal temperature of the sensor.
Please be aware that compared to the ambient temperature the indicated values are higher due to the
internal heating of the sensor.
The temperature may also vary due to mounting conditions and due to the electric load connected to the
output.
Parameter name
Device Temperature.Current
Unit Selection.Temperature
en_BA_O200_IO-Link_V1.docx
15.08.2018/
Figure 29: Dynamic Window Teach, switching behavior
Short Description
Indicates if the sensor is
working properly
Short Description
Choice of temperature unit
(Default: °C)
32/34
Rights
Unit / Allowed
values
0=Device is OK
ro
2=Out of
Specification
4=Failure
ro
Rights
Unit / Allowed
values
ro
rw
°C, °F, K
Baumer Electric AG
Frauenfeld, Switzerland