Baumer OADM 250I1101/S14C Skrócona instrukcja obsługi
Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Akcesoria Baumer OADM 250I1101/S14C. Baumer OADM 250I1101/S14C 4 stron. Photoelectric sensor
Również dla Baumer OADM 250I1101/S14C: Podręcznik (15 strony)
OADM 250I1101/S14C
Í?+Âh+ÂÂ*ÂbÎ
IND. CONT. EQ.
11007211
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Canada
Italy
Baumer Inc.
Baumer Italia S.r.l.
CA-Burlington, ON L7M 4B9
IT-20090 Assago, MI
Phone +1 (1)905 335-8444
Phone +39 (0)2 45 70 60 65
China
Singapore
Baumer (China) Co., Ltd.
Baumer (Singapore) Pte. Ltd.
CN-201612 Shanghai
SG-339412 Singapore
Phone +86 (0)21 6768 7095
Phone +65 6396 4131
Denmark
Sweden
Baumer A/S
Baumer A/S
DK-8210 Aarhus V
SE-56133 Huskvarna
Phone +45 (0)8931 7611
Phone +46 (0)36 13 94 30
France
Switzerland
Baumer SAS
Baumer Electric AG
FR-74250 Fillinges
CH-8501 Frauenfeld
Phone +33 (0)450 392 466
Phone +41 (0)52 728 1313
Germany
United Kingdom
Baumer GmbH
Baumer Ltd.
DE-61169 Friedberg
GB-Watchfield, Swindon, SN6 8TZ
Phone +49 (0)6031 60 07 0
Phone +44 (0)1793 783 839
India
USA
Baumer India Private Limited
Baumer Ltd.
IN-411038 Pune
US-Southington, CT 06489
Phone +91 20 2528 6833/34
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
1/4
25,4
4,5
LED
M12 x 1
1DD2
Technische Daten
Messdistanz Sd
Auflösung
Linearität
Wiederholpräzision (mit 40 kLux Umlicht)
Lichtquelle
Laserklasse
Messrate
Ausgangssignal
Lastwiderstand min. (analog I)
Lastwiderstand max. (analog I)
Betriebsanzeige
Alarmanzeige
Betriebsspannungsbereich Vs (UL-Class 2)
Stromaufnahme max.
Kurzschlussfest
Verpolungsfest
Arbeitstemperaturbereich
Typ. Temperaturkoeffizient
Schutzklasse
* nur Betriebsspannung / voltage supply only / plage de tension
51
39,5
7
BN (1)
WH (2)
Analog
BK (4)
GY (5)
Push Pull
BU (3)
3
Technical data
Measuring range Sd
Resolution
Linearity
Repeatability (with 40 kLux ambient light)
Light source
Laser class
Measuring rate
Output signal
Load resistance min. (analog I)
Load resistance max. (analog I)
Power on indicator
Alarm indicator
Voltage supply range Vs (UL-Class 2)
Current consumption max.
Short circuit protection
Reverse polarity protection
Operating temperature range
Typ. temp. coefficient
Protection class
+V
BN = Braun/brown/brun
S
analog
WH = Weiss/white/blanc
alarm
BK = Schwarz/black/noir
ext. teach
GY = Grau/grey/gris
Z
Z
BU = Blau/blue/bleu
0 V
Analog out
20 mA
Example
of a new
output
Standard
curve
output curve
4 mA
Alarm / LED
0
2 .
m
4
m
Données techniques
Distance de mesure Sd
Résolution
Linéarité
Reproductibilité (avec 40 kLux lumière ambiante)
Source lumineuse
Classe laser
Fréquence d'echantillonage
Signal de sortie
Résistance de charge min. (analog I)
Résistance de charge max. (analog I)
Indication de fonctionnement
Indication alarme
Plage de tension Vs (UL-Class 2)
Consommation max.
Protégé contre courts-circuits
Protégé contre inversion de polarité
Température en service
Coefficient température typ.
Classe de protection
1 = +Vs
3
4
2 = analog
5
3 = 0 V
4 = alarm
5 = ext. Teach-in
2
1
0,2 ... 4 m
1,3 mm
< ± 15 mm
± 5 mm
pulsed red laser diode
2
10 ms
4 ... 20 mA
300 Ω
(+Vs - 6V) / 0.02A
green LED
red LED ON
15 ... 28 VDC
250 mA
ja / yes / oui
ja / yes / oui *
-25 ... +50 °C
0,2 mm /°C
IP 67