8.8

Hysteresis

With the Hysteresis function you can configure the difference between the switch-on and switch-
off threshold (in mm). Without hysteresis, objects near the switching point can lead to a re-
peated switching of the switching output.
You can specify the hysteresis as a positive or negative value. The minimum value of the hys-
teresis depends on whether the hysteresis is positive or negative. In both cases, the minimum
value is selected so that the distance between the switching points equals 0. This prevents the
switching output from constantly changing its status (change between active and inactive).
Positive hysteresis
1
0
Ill. 14: Positive hysteresis
The hysteresis is situated outside the switching points (window mode) or points towards
n
higher measured values (point mode). With a positive hysteresis, the minimum distance of
the switching points is 0.
Negative hysteresis
1
0
Ill. 15: Negative hysteresis
The hysteresis is situated between the switching points (window mode) or points towards
n
lower measured values (point mode).
With a negative hysteresis, the minimum distance of the switching points is equal to the
n
value of the hysteresis times two.
OM20/OM30 | V1
Point mode
SP1
Point mode
SP1
1
0
SP1
1
0
SP1
Operating Manual
Functions
Window mode
SP2
Window mode
SP2
|
8