Baumer R600V.DAE0-11188367 Instrukcja obsługi - Strona 10

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Akcesoria Baumer R600V.DAE0-11188367. Baumer R600V.DAE0-11188367 29 stron. Radar sensor for ground & crop distance (for general applications)
Również dla Baumer R600V.DAE0-11188367: Podręcznik (4 strony)

Baumer R600V.DAE0-11188367 Instrukcja obsługi
Manual R600V.DAE0 (EN)
Fig 2
Mounting on thick soft steel plate (≥6mm).
Fig 3
Mounting on a thin soft steel plate (≥3mm)
It is recommended to use M6 screws per MBM 10105. The mounting torque for 10.9 (property
class) screws must be within 12Nm...15Nm, and for 8.8 (property class) screws it must be
within 10Nm...12Nm. For the mounting pattern and available tool space for tightening the
mounting screws please refer to the Figure below. Enough space must be allowed for the
wiring harness to avoid excessive bending of the wires or wire assembly. The wires must also
be appropriately secured and be suitable for the application.