Ill. 4: Installing encoder, mounting device and coupling
1
Drive shaft
3
Attachment device (customized)
Tools
2.5 mm
n
n
Instruction:
a) Prior to installation, check the drive runout error and dimensions.
b) Mount the encoder in a way ensuring the electrical connection is protected against direct
water ingress.
c) Apply grease onto the drive shaft.
d) Mount the attachment device (customer-specific) to the drive using the fastening screws.
e) Push coupling onto the encoder shaft and tighten to the specified torque.
K35 permitted tightening torque:
Mt = 1 ±10 % Nm (plastic side)
Mt = 1.3 ±10 % Nm (metal side)
f) Mount the encoder using suitable screws, e.g. M6x16 mm (ISO 4017) onto the B10 flange of
drive or attachment device (customer-specific).
g) Fasten the coupling on the drive shaft.
K35 Permitted tightening torque:
Mt = 1 ±10 % Nm (plastic side)
Mt = 1.3 ±10 % Nm (metal side)
Observe the remarks in the data sheet and the coupling assembly instructions.