ELECTRICAL CONNECTION / TERMINAL BOX [B]
5.2.4
Programming interface (only PMG10P)
Via connection SA and SB, encoder parameters such as additional output, switch-off
and switch-on speeds can be changed and read out� With the Z-PA�SDL�1 WLAN
adapter, available as accessory, see
web browser�
5.2.5
Switching characteristics speed switch (option)
i
The factory setting of the switching speed for the PMG10P is 6000 rpm� The
PMG10 without programming interface is delivered with the individually ordered
fixed switching speed.
Event
During initialisation
After initialisation and
speed ≤ -ns (off)
-ns (off) < speed ≤ -ns (on)
-ns (on) < speed < +ns (on)
+ns (on) ≤ speed < +ns (off)
+ns (off) ≤ speed
High resistance
Resistance between
SP+ and SP-
Low resistance
n
+ns (off) = Switch-off speed at shaft rotation in positive rotating direction*
-ns (off) = Switch-off speed at shaft rotation in negative rotating direction*
Switching hysteresis
+ns (on) = Switch-on speed at shaft rotation in positive rotating direction*
-ns (on) = Switch-on speed at shaft rotation in negative rotating direction*
* See
section 6, page 22
19/27
-n
-ns (off)
= Speed
: 5...100 % (factory setting = 10 % min. 1 Digit)
section
5.3, the encoder can be accessed via a
State of the speed switch output
High resistance (overspeed)
High resistance (overspeed)
State unchanged
Low resistance (no overspeed) after initialisation
if the device is rotating between the switching
range during initialisation�
Low resistance (no overspeed)
State unchanged
Low resistance (no overspeed) after initialisation
if the device is rotating between the switching
range during initialisation�
High resistance (overspeed)
-ns (on)
0
MB253EN - 11173971, 19A2, Baumer_PMG10-DeviceNet_II_EN
+ns (on)
+ns (off)
+n