Baumer Hubner EtherNet/IP HMG10 Instrukcja obsługi - Strona 35
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Konwerter mediów Baumer Hubner EtherNet/IP HMG10. Baumer Hubner EtherNet/IP HMG10 44 stron.
Baumer Hübner
7.1
Removing the encoder from blind hollow shafts or cone shafts
DANGER
Burns caused by heat
The device heats up at high torque. There is a risk of getting burned after use.
a) Avoid overheating the device.
b) Wear suitable gloves.
7.1.1
Loosen fastening aids provided at the blind hollow shaft
5
1
Blind hollow shaft or cone shaft with
wrench flat SW 17 mm
3
Cover
5
Grounding strap
7
Cheese-head screw M6x8 mm for
grounding strap (ISO 1207)
9
Threaded rod M6, variable length ≤ 210
mm
11 Self-locking nut M6 (ISO 10511)
V1, T1 | HMG10 & HMG10P EtherNet/IP
6
7
8
1
9
10
11
2
Cheese-head screw M6x30 mm (ISO
4762)
4
Torx/slotted head screw M4x10 mm (DIN
7964)
6
Washer B6.4 for grounding strap (ISO
7090)
8
Torque arm
10 Washer B6.4 (ISO 7090)
Operating Manual
Disassembly
2
3
4
|
7
35