Baumer Hubner PMG10 Instrukcja montażu i obsługi - Strona 28
Przeglądaj online lub pobierz pdf Instrukcja montażu i obsługi dla Konwerter mediów Baumer Hubner PMG10. Baumer Hubner PMG10 36 stron. Absolute encoder ssi with magnetic sensing
ACCESSORIES
6.2.3.2
With additional output incremental
Mating connector M23, 17-pin with sensor cable HEK 17, 17 pins assigned (2x power
supply, 1x internal shield, 10x signal, 4x data), female contacts, counter-clockwise
(CCW)
i
Suitable for first flange connector [C], see section
Cable length L
3 m
X
Programming interface (only PMG10P)
3)
Internal shield, connected with all internal shields
6)
25/29
Part number
11172463
62 mm
11
1
10
2
13
16
9
3
14
15
8
17
4
7
5
6
View X
L ±0.5%
~15 mm ~15 mm
~5 mm
PIN
WIRE
COLOUR
1
Grey
2
White/yellow
3
Black
4
Blue
5
White/black
6
Brown
7
Brown/red
8
Green/red
9
Green/black
10
Brown/blue
11
Black
5)
12
Red
13
Orange
14
Brown/yellow
15
Green
16
yellow
17
Brown/green
MB245EN - 11171693, 19A3, Baumer_PMG10-SSI_II_EN
5.8.2.1�
80 ±5 mm
WIRE CROSS-
ASSIGNMENT
SECTION
0�14 mm
2
0�14 mm
2
0�14 mm
2
0�14 mm
2
0�14 mm
2
0�14 mm
2
0�5 mm
2
0�22 mm
2
0�22 mm
2
0�5 mm
2
0�5 mm
2
0�14 mm
2
0�14 mm
2
0�22 mm
2
0�14 mm
2
0�14 mm
2
0�22 mm
2
PMG10
nE-
DIR
SB
3)
nE+
PRE
SA
3)
Ub
C+
C−
0V
---
B+
B−
D+
A+
A−
D−